Effectiveness of diode laser and fluoride on dentin hypersensitivity treatment: A randomized single-blinded clinical trial
- PMID: 32773977
- PMCID: PMC7307464
- DOI: 10.4103/jisp.jisp_478_19
Effectiveness of diode laser and fluoride on dentin hypersensitivity treatment: A randomized single-blinded clinical trial
Abstract
Background: This randomized single-blinded clinical trial aimed to evaluate the effectiveness of diode laser and fluoride in the treatment of dentin hypersensitivity (DH) due to gingival recession.
Materials and methods: Twenty-eight individuals randomly distributed across three groups participated: 10 individuals who were treated with diode laser, nine who were treated with fluoride, and nine who received placebo. Pain was assessed with the Visual analog scale (VAS). Evaporative stimulus and tactile stimulus were evaluated with the verbal rating scale (VRS). VAS was applied shortly after, 6 h after, 12 h after, and 24 h after the single-session treatment for DH, whereas VRS was applied shortly after, 15 min and 7 days after the treatment. Participants' quality of life was assessed with the validated Brazilian version of the Dentine Hypersensitivity Experience Questionnaire assessing functional limitations, coping behaviors, emotional, and social impacts caused by DH. Descriptive statistics and the ANOVA test were used. Values of P < 0.05 were statistically significant.
Results: Diode laser significantly reduced the DH to the evaporative stimulus (P = 0.002). The application of fluoride did not change the degree of DH to evaporative and tactile stimuli (P > 0.05). The group of individuals who were treated with diode laser presented a higher reduction in DH (25.4%) when compared to the group of individuals treated with fluoride (17.1%), and the group of individuals among whom placebo had been used (2.9%). Descriptive analysis indicated that the items measuring the emotional and social impacts of DH were those with a more negative impact on the individuals.
Conclusion: Therapy with diode laser was more effective in reducing DH than therapy with fluoride.
Keywords: Dentin sensitivity; fluorine; lasers; quality of life.
Copyright: © 2020 Indian Society of Periodontology.
Conflict of interest statement
There are no conflicts of interest.
Figures
Similar articles
-
Efficacy of 810 nm and 650 nm Diode Laser Alone and in Combination With Sodium Fluoride Gel in Treating Dentin Hypersensitivity: A Split-Mouth Randomized Clinical Study.Cureus. 2023 Jan 7;15(1):e33489. doi: 10.7759/cureus.33489. eCollection 2023 Jan. Cureus. 2023. PMID: 36756033 Free PMC article.
-
Clinical evaluation of Nd:YAG and 685-nm diode laser therapy for desensitization of teeth with gingival recession.Photomed Laser Surg. 2009 Dec;27(6):843-8. doi: 10.1089/pho.2008.2395. Photomed Laser Surg. 2009. PMID: 19281413 Free PMC article.
-
Low level laser therapy, Er,Cr:YSGG laser and fluoride varnish for treatment of dentin hypersensitivity after periodontal surgery: A randomized clinical trial.Lasers Med Sci. 2021 Dec;36(9):1949-1956. doi: 10.1007/s10103-021-03310-4. Epub 2021 Apr 21. Lasers Med Sci. 2021. PMID: 33881673 Clinical Trial.
-
Bioavailable gluconate chelated stannous fluoride toothpaste meta-analyses: Effects on dentine hypersensitivity and enamel erosion.J Dent. 2021 Feb;105:103566. doi: 10.1016/j.jdent.2020.103566. Epub 2020 Dec 28. J Dent. 2021. PMID: 33383100 Review.
-
Effect of dentin hypersensitivity treatment on oral health related quality of life - A systematic review and meta-analysis.J Dent. 2018 Apr;71:1-8. doi: 10.1016/j.jdent.2017.12.007. Epub 2017 Dec 17. J Dent. 2018. PMID: 29262305
Cited by
-
Clinical evaluation of the effect of 980 nm diode laser and fluoride varnish on dentin hypersensitivity.Braz Oral Res. 2025 Jul 7;39:e077. doi: 10.1590/1807-3107bor-2025.vol39.077. eCollection 2025. Braz Oral Res. 2025. PMID: 40638425 Free PMC article. Clinical Trial.
-
Effect of Low- and High-Level Laser Therapy on the Treatment of Dentin Hypersensitivity: An Umbrella Review.J Lasers Med Sci. 2024 Aug 27;15:e41. doi: 10.34172/jlms.2024.41. eCollection 2024. J Lasers Med Sci. 2024. PMID: 39381788 Free PMC article. Review.
-
Laser therapy for dentinal hypersensitivity.Cochrane Database Syst Rev. 2021 Jul 13;7(7):CD009434. doi: 10.1002/14651858.CD009434.pub2. Cochrane Database Syst Rev. 2021. PMID: 34255856 Free PMC article.
References
-
- Marto CM, Baptista Paula A, Nunes T, Pimenta M, Abrantes AM, Pires AS, et al. Evaluation of the efficacy of dentin hypersensitivity treatments-a systematic review and follow-up analysis. J Oral Rehabil. 2019;46:952–90. - PubMed
-
- Favaro Zeola L, Soares PV, Cunha-Cruz J. Prevalence of dentin hypersensitivity: Systematic review and meta-analysis. J Dent. 2019;81:1–6. - PubMed
-
- Lima TC, Vieira-Barbosa NM, Grasielle de Sá Azevedo C, de Matos FR, Douglas de Oliveira DW, de Oliveira ES, et al. Oral health-related quality of life before and after treatment of dentin hypersensitivity with cyanoacrylate and laser. J Periodontol. 2017;88:166–72. - PubMed
LinkOut - more resources
Full Text Sources