Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Oct:315:110429.
doi: 10.1016/j.forsciint.2020.110429. Epub 2020 Jul 31.

A LC-MS/MS method for determination of 73 synthetic cathinones and related metabolites in urine

Affiliations

A LC-MS/MS method for determination of 73 synthetic cathinones and related metabolites in urine

Shu-Yu Fan et al. Forensic Sci Int. 2020 Oct.

Abstract

Synthetic cathinones, which are a group of β-keto analogs of phenethylamine, have been reported as the most emerging new psychoactive substances in the past decade. The quantity and variety of synthetic cathinones have continued to increase, which poses considerable risks to public health and social security. In this study, an analytical method based on liquid chromatography-tandem mass spectrometry (LCMS/MS) was established for the simultaneous determination of 73 synthetic cathinones and related metabolites in urine. The chromatographic analysis was performed using a Kinetex® Biphenyl column (10 cm ×2.1 mm, 1.7 μm), applying a gradient mobile phase, comprising 0.1 % formic acid aqueous solution with 5 mM ammonium acetate and 0.1 % formic acid methanolic solution; the entire run time of the analysis was within 8 min. The multiple reaction monitoring (MRM) mode was employed to collect the monitoring and quantitative ion pairs. Intra-day/inter-day precision and accuracy were less than 10 % for all the studied analytes. The limits of detection and quantification for all the analytes were 0.1-0.5 ng/mL and 0.5-1.0 ng/mL, respectively. The matrix effect was satisfactory for all the analytes, with a deviation lower than 20 %. The present method was further applied to 67 authentic urine samples in which 13 different synthetic cathinones were detected from 32 positive samples. The abuse of poly-synthetic cathinones was examined that up to seven items was detected in one case from authentic samples in this study.

Keywords: Drug of abuse; LC–MS/MS; New psychoactive substance; Synthetic cathinones; Urine.

PubMed Disclaimer

MeSH terms

LinkOut - more resources