. 2020 Aug 7;20(16):4406.
doi: 10.3390/s20164406.

Flexible Ecoflex®/Graphene Nanoplatelet Foams for Highly Sensitive Low-Pressure Sensors

Affiliations

Flexible Ecoflex®/Graphene Nanoplatelet Foams for Highly Sensitive Low-Pressure Sensors

Marco Fortunato et al. Sensors (Basel). .

Abstract

The high demand for multifunctional devices for smart clothing applications, human motion detection, soft robotics, and artificial electronic skins has encouraged researchers to develop new high-performance flexible sensors. In this work, we fabricated and tested new 3D squeezable Ecoflex® open cell foams loaded with different concentrations of graphene nanoplatelets (GNPs) in order to obtain lightweight, soft, and cost-effective piezoresistive sensors with high sensitivity in a low-pressure regime. We analyzed the morphology of the produced materials and characterized both the mechanical and piezoresistive response of samples through quasi-static cyclic compression tests. Results indicated that sensors infiltrated with 1 mg of ethanol/GNP solution with a GNP concentration of 3 mg/mL were more sensitive and stable compared to those infiltrated with the same amount of ethanol/GNP solution but with a lower GNP concentration. The electromechanical response of the sensors showed a negative piezoresistive behavior up to ~10 kPa and an opposite trend for the 10-40 kPa range. The sensors were particularly sensitive at very low deformations, thus obtaining a maximum sensitivity of 0.28 kPa-1 for pressures lower than 10 kPa.

Keywords: Ecoflex®; foam; graphene; low-pressure sensor; nanoplatelets; negative piezoresistivity; positive piezoresistivity; wearable devices.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Density (a) and porosity (b) of the produced bulk and foam samples.
Figure 2
Figure 2
Schematic representation of the foam infiltration process.
Figure 3
Figure 3
Ecoflex®-based samples: bulk sample (a), open cell foam (b), GNP-loaded foam (c,d), and GNP-loaded foam with the conductive plates and wires (e).
Figure 4
Figure 4
Cross section of an Ecoflex® foam (EF) sample (a) and an EF-3% (b). Magnification of the EF-3% foam (c) and the detail of some embedded and partially emerging GNPs (d).
Figure 5
Figure 5
Stress–strain curves (a), magnification of the linear region of the stress–strain curves (b), and deformation as a function of the cyclic compressive loads (c,d) for different Ecoflex® samples during cyclic compression tests.
Figure 5
Figure 5
Stress–strain curves (a), magnification of the linear region of the stress–strain curves (b), and deformation as a function of the cyclic compressive loads (c,d) for different Ecoflex® samples during cyclic compression tests.
Figure 6
Figure 6
Compressive Young’s modulus of the Ecoflex® bulk (EB) and EF samples.
Figure 7
Figure 7
Differences in the mechanical behavior of the foam with and without the electrical contacts.
Figure 8
Figure 8
Image of the electromechanical setup.
Figure 9
Figure 9
Normalized conductance vs. pressure obtained during three consecutive quasi-static monotonic loading tests at a speed of 0.1 mm/min: response of EF-3% (a) and EFT-3% (b) samples.
Figure 10
Figure 10
Normalized conductance vs. pressure and corresponding polynomial fitting curves obtained at a speed of 0.1 (a) and 1 (b) mm/min for the EF-3% sample.
Figure 11
Figure 11
Normalized conductance vs. pressure and corresponding polynomial fitting curves obtained at a speed of 0.1 (a) and 1 (b) mm/min for the EFT-3% sample.
Figure 12
Figure 12
Normalized conductance measured during 10 consecutive loading/unloading tests of the EF (a) and EFT (b) pressure sensors.
Figure 13
Figure 13
Sensitivity of samples EF-3% (a) and the EFT-3% (b) at two different crosshead speeds.
Figure 14
Figure 14
GNP coating modification during compression and its effect on the overall normalized conductance G/G0 of the foam. (a) Normalized conductance vs. pressure for the EFT-3% sample. (bd) Zoom of the death-band zone (1st zone) and the low- (2nd zone) and medium- (3rd zone) pressure ranges of the sensor, respectively. (eg) Sketch of the effects of different pressure values on the EFT-3% pore and on the induced modification of GNP percolation paths. In particular, in the sketch, the light blue GNPs represent the completely embedded flakes, while the grey ones represent the partially embedded or surface-lying GNPs.
Figure 14
Figure 14
GNP coating modification during compression and its effect on the overall normalized conductance G/G0 of the foam. (a) Normalized conductance vs. pressure for the EFT-3% sample. (bd) Zoom of the death-band zone (1st zone) and the low- (2nd zone) and medium- (3rd zone) pressure ranges of the sensor, respectively. (eg) Sketch of the effects of different pressure values on the EFT-3% pore and on the induced modification of GNP percolation paths. In particular, in the sketch, the light blue GNPs represent the completely embedded flakes, while the grey ones represent the partially embedded or surface-lying GNPs.

References

    1. Zang Y., Zhang F., Di C., Zhu D. Advances of flexible pressure sensors toward artificial intelligence and health care applications. Mater. Horizons. 2015;2:140–156. doi: 10.1039/C4MH00147H. - DOI
    1. Liu Y., Wang H., Zhao W., Zhang M., Qin H., Xie Y. Flexible, Stretchable Sensors for Wearable Health Monitoring: Sensing Mechanisms, Materials, Fabrication Strategies and Features. Sensors. 2018;18:645. doi: 10.3390/s18020645. - DOI - PMC - PubMed
    1. Chen W., Yan X. Progress in achieving high-performance piezoresistive and capacitive flexible pressure sensors: A review. J. Mater. Sci. Technol. 2020;43:175–188. doi: 10.1016/j.jmst.2019.11.010. - DOI
    1. Li J., Fang L., Sun B., Li X., Kang S.H. Review—Recent Progress in Flexible and Stretchable Piezoresistive Sensors and Their Applications. J. Electrochem. Soc. 2020;167:037561. doi: 10.1149/1945-7111/ab6828. - DOI
    1. Yang J., Downes R., Schrand A., Park J.G., Liang R., Xu C. High electrical conductivity and anisotropy of aligned carbon nanotube nanocomposites reinforced by silicon carbonitride. Scr. Mater. 2016;124:21–25. doi: 10.1016/j.scriptamat.2016.06.023. - DOI

LinkOut - more resources