Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2020 Sep;31(9):1365-1372.
doi: 10.1016/j.jvir.2020.06.008. Epub 2020 Aug 11.

Comparison of Outcomes of Percutaneous Arteriovenous Fistulae Creation by Ellipsys and WavelinQ Devices

Affiliations
Free article
Comparative Study

Comparison of Outcomes of Percutaneous Arteriovenous Fistulae Creation by Ellipsys and WavelinQ Devices

Robert Shahverdyan et al. J Vasc Interv Radiol. 2020 Sep.
Free article

Abstract

Purpose: The purpose of this study was to compare the clinical outcomes of Ellipsys with those of WavelinQ-4F percutaneous arteriovenous fistulae (pAVF) devices in a single center by a single operator.

Materials and methods: A retrospective review was conducted in 100 patients who underwent pAVFs procedures (65 Ellipsys and 35 WavelinQ patients) and created between December 2017 and December 2019. A total of 69% were male and 37% were diabetic. Median age was 64.1 years (range: 28-86), and median body mass index was 27.2 (range: 15-45.1) kg/m2. A procedure sequence algorithm was followed for selecting all vascular accesses created.

Results: Ellipsys outcomes were compared to WavelinQ outcomes. Technical success was 100% versus 97%, respectively, and median procedure times were 14 versus 63 minutes, respectively (P < .001), with 183 (1-487) versus 185 (0-760) days follow-up, respectively. Maturation at 4 weeks was 68.3% versus 54.3%, respectively, and median times to cannulation were 60 (1-164) versus 90 (1-180) days, respectively. Successful pAVF dialysis was established in 31 of 39 patients (79.5%) versus 14 of 24 patients (58%), respectively (P = .071), dialysis patients with access-related adverse events observed in 4 individuals (1 Ellipsys versus 3 WavelinQ). Six patients (5 versus 1) with matured outflow from previous AVFs underwent first-day cannulations. Interventions were performed in 27.7% (33 Ellipsys) and 26.5% (15 WavelinQ) patients, and the number of interventions per patient-years was 0.96 versus 0.46, respectively. pAVF failure was seen in 15.4% versus 37.1% patients, respectively (P = .0137). Secondary patency at 12 months was significantly higher among patients who had an Ellipsys procedure (82%) than among those who underwent the WavelinQ procedure (60%).

Conclusions: pAVFs were created with high technical success and low complications with both devices. Ellipsys pAVFs demonstrated significantly shorter procedure times without a need for radiation exposure and with superior secondary patency.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources