Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
[Preprint]. 2020 Aug 7:2020.08.05.20168476.
doi: 10.1101/2020.08.05.20168476.

Specificity and Performance of Nucleocapsid and Spike-based SARS-CoV-2 Serologic Assays

Affiliations

Specificity and Performance of Nucleocapsid and Spike-based SARS-CoV-2 Serologic Assays

Zahra Rikhtegaran Tehrani et al. medRxiv. .

Update in

Abstract

There is an urgent need for an accurate antibody test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this paper, we have developed 3 ELISA methods, trimer spike IgA, trimer spike IgG, and nucleocapsid IgG, for detecting anti-SARS-CoV-2 antibodies. We evaluated their performance in comparison with four commercial ELISAs, EDI™ Novel Coronavirus COVID-19 ELISA IgG and IgM, Euroimmun Anti-SARS-CoV-2 ELISA IgG and IgA, and one lateral flow assay, DPP® COVID-19 IgM/IgG System (Chembio). Both sensitivity and specificity were evaluated and the causes of false-positive reactions were determined. The assays were compared using 300 pre-epidemic samples and 100 PCR-confirmed COVID-19 samples. The sensitivities and specificities of the assays were as follows: 90%/100% (in-house trimer spike IgA), 90%/99.3% (in-house trimer spike IgG), 89%/98.3% (in-house nucleocapsid IgG), 73.7%/100% (EDI nucleocapsid IgM), 84.5%/95.1% (EDI nucleocapsid IgG), 95%/93.7% (Euroimmun S1 IgA), 82.8%/99.7% (Euroimmun S1 IgG), 82.0%/91.7% (Chembio nucleocapsid IgM), 92%/93.3% (Chembio nucleocapsid IgG). The presumed causes of positive signals from pre-epidemic samples in commercial and in-house assays were mixed. In some cases, positivity varied with assay repetition. In other cases, reactivity was abrogated by competitive inhibition (spiking the sample with analyte prior to performing the assay). In other cases, reactivity was consistently detected but not abrogated by analyte spiking. Overall, there was wide variability in assay performance using our samples, with in-house tests exhibiting the highest combined sensitivity and specificity. The causes of "false positivity" in pre-epidemic samples may be due to plasma antibodies apparently reacting with the analyte, or spurious reactivity may be directed against non-specific components in the assay system. Identification of these targets will be essential to improving assay performance.

Keywords: COVID-19; Coronavirus; Immunoassay.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.. SARS-CoV-2 antibody assays data distribution.
The data obtained for pre-epidemic and COVID-19 samples with all evaluated assays. The yellow lines show the cut-off values or ranges recommended by commercial assays or calculated cutoff values for in-house ELISAs. Black lines indicate median values with interquartile ranges.

References

    1. Binley JM TA, Ketas T, Schiller D, Clas B, Little S, Richman D, Hurley A, Markowitz M, Moore JP. The effect of highly active antiretroviral therapy on binding and neutralizing antibody responses to human immunodeficiency virus type 1 infection. J Infect Dis. 2000;182(3):945–9. - PubMed
    1. Temperton NJ, Chan PK, Simmons G, Zambon MC, Tedder RS, Takeuchi Y, et al. Longitudinally profiling neutralizing antibody response to SARS coronavirus with pseudotypes. Emerg Infect Dis. 2005;11(3):411–6. - PMC - PubMed
    1. Choe PG, Perera R, Park WB, Song KH, Bang JH, Kim ES, et al. MERS-CoV Antibody Responses 1 Year after Symptom Onset, South Korea, 2015. Emerg Infect Dis. 2017;23(7):1079–84. - PMC - PubMed
    1. Tang F, Quan Y, Xin ZT, Wrammert J, Ma MJ, Lv H, et al. Lack of peripheral memory B cell responses in recovered patients with severe acute respiratory syndrome: a six-year follow-up study. J Immunol. 2011;186(12):7264–8. - PubMed
    1. Youden WJ. Index for rating diagnostic tests. Cancer. 1950;3(1):32–5. - PubMed

Publication types