Abstract
Purpose of review: This manuscript reviews recent technological advances in ambulatory urodynamics.
Recent findings: Ambulatory urodynamics is currently recommended by the International Continence Society as a second-line diagnostic tool in patients with nondiagnostic traditional urodynamics. Novel techniques involving telemetric monitoring are in development, which utilize catheter-free wireless systems to address several recognized shortcomings of inoffice urodynamic studies. Current research in catheter-free bladder pressure measurements involves either an intravesical, intradetrusor, or transdetrusor approach. Real-time bladder volume estimation may be performed using ultrasonography, near-infrared spectroscopy, or bladder volume conductance measurement. Ambulatory urodynamics can measure bladder function in the "real world" setting, capturing physiological bladder filling and emptying and allowing patients to reproduce the activities that may trigger their symptoms. Telemetric devices being developed represent further advances in this field and focus upon improving diagnostic capabilities, evaluating patient response to treatment, and facilitating closed-loop bladder control with neuroprosthetic integration.
Keywords: Ambulatory urodynamic monitoring; Bladder pressure; Telemetric; Urinary incontinence; Urodynamics; Wireless sensor.
Similar articles
-
First in Human Subjects Testing of the UroMonitor: A Catheter-free Wireless Ambulatory Bladder Pressure Monitor.J Urol. 2023 Jul;210(1):186-195. doi: 10.1097/JU.0000000000003451. Epub 2023 Jun 9. J Urol. 2023. PMID: 37293725 Free PMC article.
-
Ambulatory urodynamic monitoring: state of the art and future directions.Nat Rev Urol. 2019 May;16(5):291-301. doi: 10.1038/s41585-019-0175-5. Nat Rev Urol. 2019. PMID: 30936468 Free PMC article. Review.
-
Continuous real-time ambulatory urodynamic monitoring in infants and young children using infrared telemetry.Br J Urol. 1998 May;81 Suppl 3:76-80. doi: 10.1046/j.1464-410x.1998.00013.x. Br J Urol. 1998. PMID: 9634025
-
Differentiation of lower urinary tract dysfunctions: The role of ambulatory urodynamic monitoring.Int J Urol. 2015 May;22(5):503-7. doi: 10.1111/iju.12723. Epub 2015 Feb 24. Int J Urol. 2015. PMID: 25711671
-
Catheter-Free Urodynamics Testing: Current Insights and Clinical Potential.Res Rep Urol. 2024 Jan 3;16:1-17. doi: 10.2147/RRU.S387757. eCollection 2024. Res Rep Urol. 2024. PMID: 38192632 Free PMC article. Review.
Cited by
-
From wires to waves, a novel sensor system for in vivo pressure monitoring.Sci Rep. 2024 Mar 30;14(1):7570. doi: 10.1038/s41598-024-58019-5. Sci Rep. 2024. PMID: 38555360 Free PMC article.
-
New Imaging Techniques on the Horizon to Study Overactive and Neurogenic Bladder.Curr Bladder Dysfunct Rep. 2025;20(1):6. doi: 10.1007/s11884-025-00775-9. Epub 2025 Mar 5. Curr Bladder Dysfunct Rep. 2025. PMID: 40062201 Free PMC article. Review.
-
Paediatric urodynamic studies: emerging technologies and new frontiers.Ther Adv Urol. 2025 Feb 19;17:17562872251315927. doi: 10.1177/17562872251315927. eCollection 2025 Jan-Dec. Ther Adv Urol. 2025. PMID: 39974573 Free PMC article. Review.
-
A comprehensive survey on non-invasive wearable bladder volume monitoring systems.Med Biol Eng Comput. 2021 Aug;59(7-8):1373-1402. doi: 10.1007/s11517-021-02395-x. Epub 2021 Jul 14. Med Biol Eng Comput. 2021. PMID: 34258707 Review.
Publication types