. 2021 Jul;22(4):540-546.
doi: 10.1177/1129729820948692. Epub 2020 Aug 20.

Initial 6-month quality review of a percutaneous endovascular arteriovenous fistula program

Affiliations

Initial 6-month quality review of a percutaneous endovascular arteriovenous fistula program

Sulaiman Sultan et al. J Vasc Access. 2021 Jul.

Abstract

Background: Percutaneous arteriovenous fistulas have recently proven successful alternatives to surgical arteriovenous fistulas with encouraging initial results. The Ellipsys Endovascular Arteriovenous Fistula System utilizing ultrasound and thermal energy has recently received approval for use in the United States. At the University of New Mexico, we developed an integrated service between Vascular Surgery, Interventional Radiology, and Interventional Nephrology for percutaneous arteriovenous fistulas utilizing Ellipsys.

Methods: We performed a retrospective chart review of the initial 6 months (January 1st 2019 to July 1st 2019) of 18 percutaneous arteriovenous fistula placements to evaluate our initial technical success rate, the number of arteriovenous fistulas meeting maturation characteristics or use in dialysis, and to identify areas for quality improvement.

Results: Initial technical success was achieved in 17 out of 18 arteriovenous fistulas (94.4%). Three patients did not report for any follow-up at the end of the initial 6 months. Of the remaining patients, 7 out of 15 were using their arteriovenous fistulas or meeting maturation characteristics at the end of the study (46.7%). Patient loss to follow-up/no-show (16.7%), patient not yet requiring hemodialysis (27.8%), and poor post-surgical maturation and/or need for additional maturation procedures (55.6%) were the predominate reasons for non-use. We identified improved coordination of care, early intervention, and outpatient dialysis center education as the primary areas of focus for quality improvement.

Conclusion: Initial technical success rate of percutaneous arteriovenous fistulas placement was comparable to published studies. Early and aggressive secondary angiographic interventions of arteriovenous fistulas failing to meet cannulation requirements, improved coordination of post-operative care, and outpatient dialysis center education appear to be the primary targets for quality improvement.

Keywords: Arteriovenous fistula; Ellipsys; WavelinQ; dialysis; dialysis access; endovascular arteriovenous fistula; hemodialysis; percutaneous arteriovenous fistula; percutaneous endovascular arteriovenous fistula.