Evaluation of monoexponential extrapolation of transpulmonary thermal-dye kinetics by use of a new model-free deconvolution algorithm
- PMID: 3282155
Evaluation of monoexponential extrapolation of transpulmonary thermal-dye kinetics by use of a new model-free deconvolution algorithm
Abstract
This study evaluates the routine mathematic approach (monoexponential extrapolation) for analysis of transpulmonary thermal-dye dilution curves and estimates the effects of systemic-indicator recirculation by use of a deconvolution technique. Fifteen dogs anesthetized with N2O-piritramid were studied before and after induction of pulmonary edema by oleic acid. After introduction of central venous indicator (10 ml of a mixture of cold blood and indocyanine green dye), dilution data were recorded from the pulmonary artery and the ascending aorta. The conclusions were: (1) monoexponential extrapolation yields reasonably good estimates of the mean transit times of dye; (2) mean transit times of heat are usually overestimated by monoexponential extrapolation; (3) extravascular lung thermal volume assessed by monoexponential extrapolation is overestimated by 2.03 ml/kg of body mass under baseline conditions; and (4) the prepulmonary volume of distribution of heat exceeds that of dye by 1.4 ml/kg of body mass, thus increasing the overestimation of pulmonary extravascular heat-accessible space by the conventional technique.
Similar articles
-
[Double indicator dilution method using heat and dye to measure pulmonary extravascular water volume].J Cardiogr. 1985 Sep;15(3):787-93. J Cardiogr. 1985. PMID: 3915510 Japanese.
-
Thermal recovery after passage of the pulmonary circulation assessed by deconvolution.J Appl Physiol (1985). 1988 Mar;64(3):1210-6. doi: 10.1152/jappl.1988.64.3.1210. J Appl Physiol (1985). 1988. PMID: 3284869
-
Validity of the lagged normal density function as a model for pulmonary indicator dispersion.Biomed Instrum Technol. 1990 Jan-Feb;24(1):42-9. Biomed Instrum Technol. 1990. PMID: 2407305
-
Thermodilution measurement of lung water.Clin Chest Med. 1985 Sep;6(3):439-57. Clin Chest Med. 1985. PMID: 3907946 Review.
-
Theoretical and practical considerations of measuring extravascular lung water.J Thorac Imaging. 1988 Jul;3(3):36-43. doi: 10.1097/00005382-198807000-00010. J Thorac Imaging. 1988. PMID: 3292781 Review.
Cited by
-
Pulmonary distribution of alfentanil and sufentanil studied with system dynamics analysis.J Pharmacokinet Biopharm. 1996 Apr;24(2):197-218. doi: 10.1007/BF02353489. J Pharmacokinet Biopharm. 1996. PMID: 8875347