. 2021 Mar;406(2):251-259.
doi: 10.1007/s00423-020-01966-0. Epub 2020 Aug 21.

Quantification of fluorescence angiography: Toward a reliable intraoperative assessment of tissue perfusion - A narrative review

Affiliations
Review

Quantification of fluorescence angiography: Toward a reliable intraoperative assessment of tissue perfusion - A narrative review

Christian Dam Lütken et al. Langenbecks Arch Surg. 2021 Mar.

Abstract

Background: Accurate intraoperative assessments of tissue perfusion are essential in all forms of surgery. As traditional methods of perfusion assessments are not available during minimally invasive surgery, novel methods are required. Here, fluorescence angiography with indocyanine green has shown promising results. However, to secure objective and reproducible assessments, quantification of the fluorescent signal is essential (Q-ICG). This narrative review aims to provide an overview of the current status and applicability of Q-ICG for intraoperative perfusion assessment.

Results: Both commercial and custom Q-ICG software solutions are available for intraoperative use; however, most studies on Q-ICG have performed post-operative analyses. Q-ICG can be divided into inflow parameters (ttp, t0, slope, and T1/2max) and intensity parameters (Fmax, PI, and DR). The intensity parameters appear unreliable in clinical settings. In comparison, inflow parameters, mainly slope, and T1/2max have had superior clinical performance.

Conclusion: Intraoperative Q-ICG is clinically available; however, only feasibility studies have been performed, rendering an excellent usability score. Q-ICG in a post-operative setting could detect changes in perfusion following a range of interventions and reflect clinical endpoints, but only if based on inflow parameters. Thus, future studies should include the methodology outlined in this review, emphasizing the use of inflow parameters (slope or T1/2max), a mass-adjusted ICG dosing, and a fixed camera position.

Keywords: Indocyanine green; Intraoperative; Optimization; Perfusion assessment; Quantitative fluorescence angiography.

PubMed Disclaimer

References

    1. Matienzo D, Bordoni B (2020) Anatomy, blood flow, in StatPearls. StatPearls Publishing. Copyright © 2020, StatPearls Publishing LLC., Treasure Island (FL).
    1. Robson MC, Steed DL, Franz MG (2001) Wound healing: biologic features and approaches to maximize healing trajectories. Curr Probl Surg 38(2):72–140 - PubMed
    1. Shandall A, Lowndes R, Young HL (1985) Colonic anastomotic healing and oxygen tension. Br J Surg 72(8):606–609 - PubMed
    1. Thompson SK, Chang EY, Jobe BA (2006) Clinical review: healing in gastrointestinal anastomoses, part I. Microsurgery 26(3):131–136 - PubMed
    1. Kassis ES et al (2013) Predictors of anastomotic leak after esophagectomy: an analysis of the society of thoracic surgeons general thoracic database. Ann Thorac Surg 96(6):1919–1926 - PubMed

LinkOut - more resources