Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Sep;40(6):639-648.
doi: 10.1002/micr.30640. Epub 2020 Aug 21.

Microsurgical reconstruction of extensive lower extremity defects with the conjoined parascapular and latissimus dorsi free flap

Affiliations

Microsurgical reconstruction of extensive lower extremity defects with the conjoined parascapular and latissimus dorsi free flap

Amir K Bigdeli et al. Microsurgery. 2020 Sep.

Abstract

Background: Extensive lower extremity soft-tissue defects pose a reconstructive challenge. We present our experience with the conjoined parascapular and latissimus dorsi (CPLD) free flap.

Methods: From October 2008 to October 2017, 69 patients (14 female, 55 male) with a mean age of 50 years (range: 16-79 years) underwent reconstruction of lower extremity defects with the CPLD free flap. Mean defect size was 24 × 36 cm (range: 14 × 20 to 45 × 80 cm).

Results: Mean latissimus dorsi (LD) flap size was 19 × 28 cm (range: 14 × 20 to 28 × 42 cm) and mean parascapular (PSC) flap size was 8 × 25 cm (range: 5 × 12 to 11 × 33 cm). Six patients (9%) experienced a total of eight microvascular complications: arterial thrombosis (n = 1), venous thrombosis (n = 6), combined arterial and venous thrombosis (n = 1). The re-exploration rate was 13%. Major complications of the donor-site were seen in 9 patients (13%), of the flap in 13 patients (19%), and of both in 6 patients (9%). Fifteen patients experienced partial flap necrosis (22%). Three CPLD and one PSC flap were lost (5%). PSC flap length was a significant predictor of distal flap necrosis (χ2 (1) = 13.2, p = .004, OR = 1.343, 95% CI [1.098-1.642]). PSC flap width was a significant predictor of donor-site revisions (χ2 (1) = 15.9, p = .010, OR = 4.745, 95% CI [1.584-14.213]). Arterio-venous loops (AVLs) tended to increase the risk of microvascular thrombosis (χ2 (1) = 3.7, p = .08, OR = 4.1, 95% CI [0.9-18.7]).

Conclusions: The CPLD free flap is an extremely large and highly reliable flap, allowing one-stage reconstruction of extensive lower extremity defects. It may overcome the need for multiple flaps in selected cases.

PubMed Disclaimer

References

REFERENCES

    1. Bartlett, S. P., May, J. W., & Yaremchuk, M. J. (1981). The latissimus dorsi muscle: A fresh cadaver study of the primary neurovascular pedicle. Plastic and Reconstructive Surgery, 67(5), 631-636.
    1. Bigdeli, A. K., Gazyakan, E., Schmidt, V. J., Bauer, C., Germann, G., Radu, C. A., … Hirche, C. (2019). Long-term outcome after successful lower extremity free flap salvage. Journal of Reconstructive Microsurgery, 35(4), 263-269.
    1. Bigdeli, A. K., Gazyakan, E., Schmidt, V. J., Hernekamp, F. J., Harhaus, L., Henzler, T., … Hirche, C. (2016). Indocyanine green fluorescence for free-flap perfusion imaging revisited: Advanced decision making by virtual perfusion reality in visionsense fusion imaging angiography. Surgical Innovation, 23(3), 249-260.
    1. Bigdeli, A. K., Thomas, B., Schmidt, V. J., Kotsougiani, D., Hernekamp, F. J., Hirche, C., … Gazyakan, E. (2018). The conjoined parascapular and latissimus dorsi free flap for reconstruction of extensive knee defects. Microsurgery, 38(8), 867-875.
    1. Chang, E. I. (2013). My first 100 consecutive microvascular free flaps: Pearls and lessons learned in first year of practice. Plastic and Reconstructive Surgery, 1(4), e27.