Automated sample preparation for the detection and confirmation of hypoxia-inducible factor stabilizers in urine
- PMID: 32840903
- DOI: 10.1002/bmc.4970
Automated sample preparation for the detection and confirmation of hypoxia-inducible factor stabilizers in urine
Abstract
As hypoxia-inducible factor stabilizers (HIFs) can artificially enhance an athlete's erythropoiesis, the World Anti-Doping Agency prohibits their use at all times. Every urine sample for doping control analysis has to be evaluated for the presence of HIFs and therefore sensitive methods that allow high sample throughput are needed. Samples suspicious for the presence of HIFs need to be confirmed following the identification criteria established by the World Anti-Doping Agency. Previous work has shown the advantages of using turbulent flow online solid-phase extraction (SPE) procedures to reduce matrix effects and retention time shifts. Furthermore, the use of online SPE allows for automation and high sample throughput. Both an initial testing procedure (ITP) and a confirmation method were developed and validated, using online SPE liquid chromatography-tandem mass spectrometry (LC-MS/MS), with limits of detection between 0.1 ng/ml (or possibly lower) and 4 ng/ml (or higher for GSK360a) and limits of identification between 0.1 ng/ml (or possibly lower) and 1.17 ng/ml. The ITP only takes 6.5 min per sample. To the best of our knowledge, these are the first ITP and confirmation methods that include more than three HIFs without the need for manual sample preparation.
Keywords: LC-MS/MS; doping; hypoxia-inducible factor stabilizers; turbulent flow online SPE; urine.
© 2020 John Wiley & Sons, Ltd.
References
REFERENCES
-
- Abushareeda, W., Vonaparti, A., Al Saad, K., Almansoori, M., Meloug, M., Saleh, A., … Georgakopoulos, C. (2018). High resolution full scan liquid chromatography mass spectrometry comprehensive screening in sports antidoping urine analysis. Journal of Pharmaceutical and Biomedical Analysis, 151, 10-24. https://doi.org/10.1016/j.jpba.2017.12.025
-
- Asakawa, Y., Ozawa, C., Osada, K., Kaneko, S., & Asakawa, N. (2007). Reduction of carry-over in column-switching HPLC/MS system with automated system washing procedure for highly sensitive direct analysis of donepezil in dog plasma. Journal of Pharmaceutical and Biomedical Analysis, 43(2), 683-690. https://doi.org/10.1016/j.jpba.2006.08.007
-
- Badoud, F., Grata, E., Perrenoud, L., Avois, L., Saugy, M., Rudaz, S., & Veuthey, J. L. (2009). Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. I. Screening analysis. Journal of Chromatography A, 1216(20), 4423-4433. https://doi.org/10.1016/j.chroma.2009.03.033
-
- Badoud, F., Guillarme, D., Boccard, J., Grata, E., Saugy, M., Rudaz, S., & Veuthey, J. L. (2011). Analytical aspects in doping control: Challenges and perspectives. Forensic Science International, 213(1-3), 49-61. https://doi.org/10.1016/j.forsciint.2011.07.024
-
- Beuck, S., Schänzer, W., & Thevis, M. (2012). Hypoxia-inducible factor stabilizers and other small-molecule erythropoiesis-stimulating agents in current and preventive doping analysis. Drug Testing and Analysis, 4(11), 830-845. https://doi.org/10.1002/dta.390
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
