. 2020 Jul-Aug;138(4):310-316.
doi: 10.1590/1516-3180.2020.014605062020.

Diagnostic accuracy of preoperative magnetic resonance imaging for detecting subscapularis tendon tears: a diagnostic test study

Affiliations

Diagnostic accuracy of preoperative magnetic resonance imaging for detecting subscapularis tendon tears: a diagnostic test study

Lucas Busnardo Ramadan et al. Sao Paulo Med J. 2020 Jul-Aug.

Abstract

Background: The accuracy of magnetic resonance imaging (MRI) for making the diagnosis of subscapularis tears presents wide variation in the literature and there are few prospective studies.

Objective: To compare the findings from MRI and arthroscopy for diagnosing subscapularis tears.

Design and setting: Diagnostic test study performed in a tertiary care hospital.

Methods: We included patients who underwent arthroscopic rotator cuff repair and who had firstly undergone high magnetic field MRI without contrast. The images were independently evaluated by a shoulder surgeon and two musculoskeletal radiologists. Sensitivity, specificity, positive and negative predictive values, accuracy and inter and intra-observer agreement were calculated.

Results: MRIs on 200 shoulders were evaluated. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% full-thickness). The inter and intra-observer agreement was moderate for detection of subscapularis tears. The shoulder surgeon presented sensitivity of 51.1% to 59.0% and specificity of 91.7% to 94.4%. The radiologists showed sensitivity of 83.5% to 87.1% and specificity of 41% to 45.9%. Accuracy ranged from 60.5% to 73.0%.

Conclusion: The 1.5-T MRIs without contrast showed mean sensitivity of 70.2% and mean specificity of 61.9% for detection of subscapularis tears. Sensitivity was higher for the musculoskeletal radiologists, while specificity was higher for the shoulder surgeon. The mean accuracy was 67.6%, i.e. lower than that of rotator cuff tears overall.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: None

Similar articles

Cited by

References

    1. Su WR, Budoff JE, Luo ZP. The effect of posterosuperior rotator cuff tears and biceps loading on glenohumeral translation. Arthroscopy. 2010;26(5):578–586. doi: 10.1016/j.arthro.2009.09.007. - DOI - PubMed
    1. Collin P, Matsumura N, Lädermann A, Denard PJ, Walch G. Relationship between massive chronic rotator cuff tear pattern and loss of active shoulder range of motion. J Shoulder Elbow Surg. 2014;23(8):1195–1202. doi: 10.2106/JBJS.I.01531. - DOI - PubMed
    1. Pfirrmann CW, Zanetti M, Weishaupt D, Gerber C, Hodler J. Subscapularis tendon tears: detection and grading at MR arthrography. Radiology. 1999;213(3):709–714. doi: 10.1148/radiology.213.3.r99dc03709. - DOI - PubMed
    1. Lo IKY, Burkhart SS. Subscapularis Tears: Arthroscopic Repair of the Forgotten Rotator Cuff Tendon. Techniques in Shoulder and Elbow Surgery. 2002;3(4):282–291.
    1. Garavaglia G, Ufenast H, Taverna E. The frequency of subscapularis tears in arthroscopic rotator cuff repairs: A retrospective study comparing magnetic resonance imaging and arthroscopic findings. Int J Shoulder Surg. 2011;5(4):90–94. doi: 10.4103/0973-6042.91000. - DOI - PMC - PubMed

Publication types