Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan;24(1):91-100.
doi: 10.1080/10255842.2020.1811980. Epub 2020 Aug 26.

Effect of umbilical cord length on early fetal biomechanics

Affiliations

Effect of umbilical cord length on early fetal biomechanics

Juan Felipe Sánchez Gutiérrez et al. Comput Methods Biomech Biomed Engin. 2021 Jan.

Abstract

The umbilical cord suspends the fetus within the amniotic cavity, where fetal dynamics is one of its many functions. Hence, the umbilical cord is a viable index in determining fetal activity. Fetal movements result in mechanical loads that are fundamental for fetal growth. At present, mechanical environment during early human fetal development is still largely unknown. To determine early fetal movement dynamics at given physiological (0.060 m) and pathological umbilical cord lengths (0.030 m, 0.020 m, 0.017 m and 0.014 m) a 2D computational model was created to simulate dynamic movement conditions. Main findings of this computational model revealed the shortest umbilical cord length (0.014 m) with a 6(10-6)N, twitch force amplitude had a two-fold increase on linear velocity (0.12 m/s) in comparison with other lengths (0.05m/s). Moreover, umbilical cord length effect presented an increasing exponential tension on the fetus body wall from longest to shortest, from 0 N in the control length to 0.05 N for the shortest umbilical cord. Last, tension was always present over a period of time for the shortest cord (0.03 N to 0.08 N). Collectively, for all variables evaluated the shortest umbilical cord (0.014 m) presented remarkable differences with other lengths in particular with the second shortest umbilical cord (0.017 m), suggesting a 0.003 m difference represents a greater biomechanical effect. In conclusion, this computational model brings new insights required by clinicians, where the magnitude of these loads could be associated with different pathologies found in the clinic.

Keywords: Umbilical cord length; biomechanics; fetal movements; tension.

PubMed Disclaimer

LinkOut - more resources