Time of PTV is ending, robust optimization comes next
- PMID: 32861608
- DOI: 10.1016/j.canrad.2020.06.016
Time of PTV is ending, robust optimization comes next
Abstract
Continuous improvements have been made in the way to prescribe, record and report dose distributions since the therapeutic use of ionizing radiations. The international commission for radiation units and measurement (ICRU) has provided a common language for physicians and physicists to plan and evaluate their treatments. The PTV concept has been used for more than two decades but is becoming obsolete as the CTV-to-PTV margin creates a static dose cloud that does not properly recapitulate all planning vs. delivery uncertainties. The robust optimization concept has recently emerged to overcome the limitations of the PTV concept. This concept is integrated in the inverse planning process and minimizes deviations to planned dose distribution through integration of uncertainties in the planning objectives. It appears critical to account for the uncertainties that are specific to protons and should be accounted for to better exploit the clinical potential of proton therapy. It may also improve treatment quality particularly in hypofractionated photon plans of mobile tumors and more widely to photon radiotherapy. However, in contrast to the PTV concept, a posteriori evaluation of plan quality, called robust evaluation, using error-based scenarios is still warranted. Robust optimization metrics are warranted. These metrics are necessary to compare PTV-based photon and robustly optimized proton plans in general and in model-based NTCP approaches. Assessment of computational demand and approximations of robust optimization algorithms along with metrics to evaluate plan quality are needed but a step further to better prescribe radiotherapy may has been achieved.
Keywords: CTV; Incertitudes; Optimisation robuste; PTV; Radiotherapy; Radiothérapie; Robust optimization; Uncertainties; volume cible anatomoclinique; volume cible prévisionnel.
Copyright © 2020. Published by Elsevier Masson SAS.
Similar articles
-
Robust mixed electron-photon radiation therapy optimization.Med Phys. 2019 Mar;46(3):1384-1396. doi: 10.1002/mp.13381. Epub 2019 Feb 14. Med Phys. 2019. PMID: 30628079
-
Practical robustness evaluation in radiotherapy - A photon and proton-proof alternative to PTV-based plan evaluation.Radiother Oncol. 2019 Dec;141:267-274. doi: 10.1016/j.radonc.2019.08.005. Epub 2019 Sep 3. Radiother Oncol. 2019. PMID: 31492443
-
Comparison of linear and nonlinear programming approaches for "worst case dose" and "minmax" robust optimization of intensity-modulated proton therapy dose distributions.J Appl Clin Med Phys. 2017 Mar;18(2):15-25. doi: 10.1002/acm2.12033. Epub 2017 Mar 13. J Appl Clin Med Phys. 2017. PMID: 28300378 Free PMC article.
-
[Uncertainties in the current concept of radiotherapy planning target volume].Cancer Radiother. 2020 Oct;24(6-7):667-675. doi: 10.1016/j.canrad.2020.06.004. Epub 2020 Aug 20. Cancer Radiother. 2020. PMID: 32828670 Review. French.
-
Robust Proton Treatment Planning: Physical and Biological Optimization.Semin Radiat Oncol. 2018 Apr;28(2):88-96. doi: 10.1016/j.semradonc.2017.11.005. Semin Radiat Oncol. 2018. PMID: 29735195 Free PMC article. Review.
Cited by
-
Comparative Study of Plan Robustness for Breast Radiotherapy: Volumetric Modulated Arc Therapy Plans with Robust Optimization versus Manual Flash Approach.Diagnostics (Basel). 2023 Nov 7;13(22):3395. doi: 10.3390/diagnostics13223395. Diagnostics (Basel). 2023. PMID: 37998531 Free PMC article.
-
Treatment plan comparison of proton vs photon radiotherapy for lower-grade gliomas.Phys Imaging Radiat Oncol. 2021 Nov 28;20:98-104. doi: 10.1016/j.phro.2021.11.008. eCollection 2021 Oct. Phys Imaging Radiat Oncol. 2021. PMID: 34888422 Free PMC article.
-
Application of Photon-Derived Worst-Case Robustness Criteria to Proton Therapy Planning.Int J Part Ther. 2025 Feb 12;15:100740. doi: 10.1016/j.ijpt.2025.100740. eCollection 2025 Mar. Int J Part Ther. 2025. PMID: 40061450 Free PMC article.
-
Error on the stopping power ratio of ERKODENT's mouthpiece for head and neck carbon ion radiotherapy treatment.J Appl Clin Med Phys. 2023 May;24(5):e13987. doi: 10.1002/acm2.13987. Epub 2023 Apr 5. J Appl Clin Med Phys. 2023. PMID: 37018016 Free PMC article.
-
A robust optimization model for intensity-modulated radiotherapy: Cheap-Minimax.Med Phys. 2025 May;52(5):3360-3376. doi: 10.1002/mp.17709. Epub 2025 Feb 26. Med Phys. 2025. PMID: 40012139 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical