. 1988 May-Jun;8(3):652-7.
doi: 10.1002/hep.1840080336.

Morphological and hemodynamic changes in the portal venous system after distal splenorenal shunt: an ultrasound and pulsed Doppler study

Affiliations

Morphological and hemodynamic changes in the portal venous system after distal splenorenal shunt: an ultrasound and pulsed Doppler study

L Bolondi et al. Hepatology. 1988 May-Jun.

Abstract

We investigated a group of patients who underwent distal splenorenal shunt using high-resolution real-time equipment and a duplex scanner with the aims: (i) to evaluate the rate of visualization of shunt; (ii) to assess change in size in the portal vein, and (iii) to characterize the flow pattern in the splenic vein and to study flow direction and velocity in the portal vein, thus adding new data on the efficacy of this operation in maintaining hepatic perfusion. Real-time ultrasonography was performed in 29 patients before surgery, after 7 to 30 days and after 4 to 12 months. Direct visualization of the shunt was achieved in 53.5% of the patients. Mean caliber of the portal vein significantly decreased after the operation: preoperative = 1.52 +/- 0.32; after 7 to 30 days = 1.32 +/- 0.16 (p less than 0.001), and after 4 to 12 months = 0.99 +/- 0.19 (p less than 0.001). The overall postoperative incidence of portal thrombosis was 22.2%. Thirteen of these patients also underwent a postoperative (4 to 36 months) pulsed Doppler investigation. Flow towards anastomosis was demonstrated in the splenic vein in 11 patients, and in 7 cases, typical caval pulsatility was observed. Decreased hepatopetal flow in the portal vein was found in 10 of 13 patients. In two patients, no flow was detectable and in the other the flow was hepatofugal. On the basis of our data, we can affirm that pulsed Doppler investigation may provide useful data for the evaluation of shunt patency and preservation of a decreased portal hepatic perfusion in the majority of patients.

PubMed Disclaimer

MeSH terms

LinkOut - more resources