Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2020 Sep 1;29(5):371-378.
doi: 10.4037/ajcc2020129.

Intubation Setting, Aspiration, and Ventilator-Associated Conditions

Affiliations
Randomized Controlled Trial

Intubation Setting, Aspiration, and Ventilator-Associated Conditions

Steven Talbert et al. Am J Crit Care. .

Abstract

Background: Patients experience endotracheal intubation in various settings with wide-ranging risks for postintubation complications such as aspiration and ventilator-associated conditions.

Objectives: To evaluate associations between intubation setting, presence of aspiration biomarkers, and clinical outcomes.

Methods: This study is a subanalysis of data from the NO-ASPIRATE single-blinded randomized clinical trial. Data were prospectively collected for 513 adult patients intubated within 24 hours of enrollment. Patients with documented aspiration events at intubation were excluded. In the NO-ASPIRATE trial, intervention patients received enhanced oropharyngeal suctioning every 4 hours and control patients received sham suctioning. Tracheal specimens for α-amylase and pepsin tests were collected upon enrollment. Primary outcomes were ventilator hours, lengths of stay, and rates of ventilator-associated conditions.

Results: Of the baseline tracheal specimens, 76.4% were positive for α-amylase and 33.1% were positive for pepsin. Proportions of positive tracheal α-amylase and pepsin tests did not differ significantly between intubation locations (study hospital, transfer from other hospital, or field intubation). No differences were found for ventilator hours or lengths of stay. Patients intubated at another hospital and transferred had significantly higher ventilator-associated condition rates than did those intubated at the study hospital (P = .02). Ventilator-associated condition rates did not differ significantly between patients intubated in the field and patients in other groups.

Conclusions: Higher ventilator-associated condition rates associated with interhospital transfer may be related to movement from bed, vehicle loading and unloading, and transport vehicle vibrations. Airway assessment and care may also be suboptimal in the transport environment.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Breckwoldt J, Klemstein S, Brunne B, Schnitzer L, Mochmann HC, Arntz HR. Difficult prehospital endotracheal intubation: predisposing factors in a physician based EMS. Resuscitation. 2011;82(12):1519–1524. - PubMed
    1. Burns B, Habig K, Eason H, Ware S. Difficult intubation factors in prehospital rapid sequence intubation by an Australian helicopter emergency medical service. Air Med J. 2016; 35(1):28–32. - PubMed
    1. Prekker ME, Kwok H, Shin J, Carlbom D, Grabinsky A, Rea TD. The process of prehospital airway management: challenges and solutions during paramedic endotracheal intubation. Crit Care Med. 2014;42(6):1372–1378. - PMC - PubMed
    1. Fawcett VJ, Warner KJ, Cuschieri J, et al. Pre-hospital aspiration is associated with increased pulmonary complications. Surg Infect (Larchmt). 2015;16(2):159–164. - PubMed
    1. Hansen M, Lambert W, Guise JM, Warden CR, Mann NC, Wang H. Out-of-hospital pediatric airway management in the United States. Resuscitation. 2015;90:104–110. - PMC - PubMed

Publication types