Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan 15:323:100-105.
doi: 10.1016/j.ijcard.2020.08.089. Epub 2020 Aug 29.

Comparison of transvenous vs subcutaneous defibrillator therapy in patients with cardiac arrhythmia syndromes and genetic cardiomyopathies

Affiliations

Comparison of transvenous vs subcutaneous defibrillator therapy in patients with cardiac arrhythmia syndromes and genetic cardiomyopathies

Jürgen Kuschyk et al. Int J Cardiol. .

Abstract

Background: Inherited arrhythmia syndromes and genetic cardiomyopathies attribute in a significant proportion to sudden cardiac death. Implantable cardioverter defibrillators (ICDs) are the cornerstone in the prevention of sudden death in high-risk patients. However, ICD therapy is also associated with high rates of inappropriate shocks and/or device-related complications especially in young patients.

Objective: To determine the outcome of high-risk patients with inherited arrhythmia syndromes and genetic cardiomyopathies comparing two defibrillator technologies.

Method: Between 2010 and 2018, 183 consecutive patients from two large German tertiary care centers were enrolled in the study. The majority of patients (83%) had either cardiac channelopathies or idiopathic ventricular fibrillation without cardiac structural abnormalities, while the remaining 17% had a genetic cardiomyopathy (HCM/ARVC). Eighty-six patients (47%) received a transvenous ICD (TV-ICD), while a subcutaneous ICD (S-ICD) was implanted in another 97 patients (53%).

Results: During a mean follow-up of 4.3 years, 30 patients had an appropriate ICD therapy (annual rate 3.8%). Fifteen patients experienced an inappropriate shock (annual rate 1.9%). Lead failure occurred in 17 (9%) patients and was less frequent in the S-ICD group (OR 0.48, 95%CI 0.38-0.62). Adverse defibrillator events, defined as a composite of inappropriate shocks and lead failure requiring surgical revision were significantly lower in the S-ICD group as compared to the TV-ICD group (OR 0.55, 95%CI 0.41-0.72). There was a non-significant trend towards lower appropriate shocks in the S-ICD group, that in combination with all-cause shocks yielded in a significantly higher freedom of any shock in the S-ICD group (RR 39%, p = 0.003). No deaths occurred during follow-up.

Conclusion: The present data favor the use of the subcutaneous ICD for patients with inherited arrhythmia syndromes and genetic cardiomyopathies who do not need anti-bradycardia pacing.

Keywords: Appropriate shock; Inappropriate shock; Inherited arrhythmia syndromes; Lead failure; Lead fracture; Subcutaneous defibrillator; Sudden cardiac death; Transvenous defibrillator; Ventricular fibrillation; Ventricular tachycardia.