Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Sep 2;17(17):6381.
doi: 10.3390/ijerph17176381.

Evaluation of Fecal Coliform Prevalence and Physicochemical Indicators in the Effluent from a Wastewater Treatment Plant in the North-West Province, South Africa

Affiliations

Evaluation of Fecal Coliform Prevalence and Physicochemical Indicators in the Effluent from a Wastewater Treatment Plant in the North-West Province, South Africa

Stenly Makuwa et al. Int J Environ Res Public Health. .

Abstract

Compliance of the effluents from wastewater treatment plants (WWTPs) to the regulatory standards, which mostly entail the removal/reduction of organic waste and deactivation of the potential microbial pathogens is of great importance. The detection of indicator parameters can be used to determine the effectiveness of a WWTP and the level of compliance with the South African regulatory standards. The performance of the WWTP was assessed by biological, physical and chemical measures in wastewater final effluent. The Escherichia coli ranged from 0 and 2420 count/100 mL in the final effluent. The recorded values for the physicochemical parameters were within the following ranges: pH (7.03-8.49), electrical conductivity (81.63-126.5 mS/m), suspended solids (0.40-20.4 mg/L), ammonia (0-22.15 mg/L), Chemical Oxygen Demand (COD) (1-73 mg/L), nitrate (0-16.1 mg/L), ortho-phosphate (0-8.58 mg/L) and free chlorine (0-3.21 mg/L). Furthermore, the concentration of toxic heavy metals was recorded to be between 1-10 ug/L for arsenic, cadmium, lead and mercury. In conclusion, all the parameters that were evaluated in this study indicate that the studied WWTP is performing in accordance with the prescribed general limits.

Keywords: E. coli; effluent; general limits; green drop; heavy metals; influent; physicochemical; special limits; wastewater.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

Figures

Figure 1
Figure 1
Assessment of the data to green drop compliance.

References

    1. Mara D., Horan N. Handbook of Water and Wastewater Microbiology. Elsevier; Amsterdam, The Netherlands: 2003.
    1. Benit N., Roslin A.S. Physicochemical properties of wastewater collected from different sewage sources. Int. J. Innov. Sci. Eng. Technol. 2015;2:691–696.
    1. US EPA . Terms of Environment: Glossary, Abbreviations, and Acronyms. Office of the Administrator/Office of External Affairs and Environmental Education; Washington, DC, USA: 2009.
    1. Agoro M.A., Okoh O.O., Adefisoye M.A., Okoh A.I. Physicochemical properties of wastewater in three typical South African sewage works. Polish J. Environ. Stud. 2018 doi: 10.15244/pjoes/74156. - DOI
    1. Salgot M., Folch M. Wastewater treatment and water reuse. Curr. Opin. Environ. Sci. Health. 2018 doi: 10.1016/j.coesh.2018.03.005. - DOI

Publication types

LinkOut - more resources