Intraventricular Conduction Disturbances After Transcatheter Aortic Valve Implantation
- PMID: 32905123
- PMCID: PMC7463330
- DOI: 10.15420/icr.2020.07
Intraventricular Conduction Disturbances After Transcatheter Aortic Valve Implantation
Erratum in
-
Corrigendum to: Intraventricular Conduction Disturbances After Transcatheter Aortic Valve Implantation.Interv Cardiol. 2020 Nov 24;15:e17. doi: 10.15420/icr.2020.33. eCollection 2020 Apr. Interv Cardiol. 2020. PMID: 33318753 Free PMC article.
Abstract
Despite significant improvements in transcatheter aortic valve implantation (TAVI) outcomes, periprocedural conduction disturbances, such as new-onset left bundle branch block (LBBB) and new pacemaker implantation (PMI), remain relatively frequent concerns. The development of periprocedural conduction disturbances can be explained by the proximity between the aortic valve and the conduction system. Although prior studies reported heterogeneity in PMI rates after TAVI, current evidence supports the potentially deleterious consequence of LBBB and PMI, and several predisposing factors have been reported. Therefore, new strategies to avoid conduction disturbances and to improve their management are required, particularly with the current trend to expand TAVI to a low-risk population.
Keywords: Transcatheter aortic valve implantation; conduction abnormality; left bundle branch block; pacemaker implantation.
Copyright © 2020, Radcliffe Cardiology.
Conflict of interest statement
Disclosure: MM has been a consultant for Japan Lifeline. APT is supported by Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Brazil (Finance Code 001). RP has received consulting fees from Medtronic and has minor equity in Centerline Biomedical. FM has received grant and/or research support from Abbott, Medtronic, Edwards Lifesciences, Biotronik, Boston Scientific Corporation, NVT and Terumo; receives consulting fees and honoraria from Abbott, Medtronic, Edwards Lifesciences, SwissVortex, Perifect, Xeltis, Transseptal Solutions, Cardiovalve and Magenta; has royalty income or intellectual property rights from Edwards Lifesciences; and is a shareholder of Cardiovalve, Cardiogard, Magenta, SwissVortex, Transseptal Solutions, 4Tech and Perifect. MT is a consultant for Abbott Vascular, Boston Scientific, 4tech and CoreMedic; and has received speaker honoraria from Edwards Lifesciences. All other authors have no conflicts of interest to declare.
Figures
References
-
- De Torres-Alba F, Kaleschke G, Diller GP et al. Changes in the pacemaker rate after transition from Edwards SAPIEN XT to SAPIEN 3 transcatheter aortic valve implantation: the critical role of valve implantation height. JACC Cardiovasc Interv. 2016;9:805–13. doi: 10.1016/j.jcin.2015.12.023. - DOI - PubMed
Publication types
LinkOut - more resources
Full Text Sources
