Transvenous revision of leads with cardiac perforation following device implantation-Safety, outcome, and complications
- PMID: 32909622
- DOI: 10.1111/pace.14056
Transvenous revision of leads with cardiac perforation following device implantation-Safety, outcome, and complications
Abstract
Introduction: Cardiac perforation is a rare complication of cardiac implantable electronic device (CIED) implantation. Transvenous revision of perforated leads is associated with the risk of cardiac tamponade and death. Little is known about periprocedural complications and outcome of these patients.
Methods and results: All patients referred to our department with evidence or suspicion of cardiac perforation following CIED implantation underwent chest X-ray, transthoracic echocardiography, device interrogation, and, if necessary, a cardiac computed tomography (CT)-scan to diagnose lead perforation and associated complications. Transvenous lead revision (TLR) was performed in all patients with evidence of lead perforation. Patient characteristics, procedural complications, and outcome were recorded and analyzed. Fifty-six patients (75 ± 10 years, 43% male) were diagnosed with cardiac perforation, 34 patients (61%) early within 30 days post-implantation, and 22 patients (39%) thereafter. The most frequent perforation site was the right ventricular (RV) apex (75%), followed by the RV free wall (16%) and the right atrial appendage (9%). A total of 16 patients (29%) presented with severe complications; 12 patients (21%) with pericardial effusion treated by pericardiocentesis before lead revision and four patients (7%) with hematothorax requiring drainage. Late perforations showed significantly more frequent cardiac tamponades (P = .041). TLR was performed without further complications in 54 patients (96%). None of the patients required surgical treatment or experienced in-hospital death.
Conclusions: Cardiac perforation following CIED implantation is associated with severe complications in nearly one-third of the cases. Transvenous revision of the perforated lead can safely be performed with a very low complication rate.
Keywords: cardiac perforation; defibrillator lead; pacemaker lead; transvenous lead extraction.
© 2020 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals LLC.
References
REFERENCES
-
- Brignole M, Auricchio A, Baron-Esquivias G, et al. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J. 2013;34:2281-2329.
-
- Priori SG, Blomstrom-Lundqvist C, Mazzanti A, et al. 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2015;36:2793-252867.
-
- Ponikowski P, Voors AA, Anker SD, et al. 2016 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure: the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC). Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. Eur Heart J. 2016;37:2129-2200.
-
- Kirkfeldt RE, Johansen JB, Nohr EA, Jorgensen OD, Nielsen JC. Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J. 2014;35:1186-1194.
-
- Sterlinski M, Przybylski A, Maciag A, et al. Subacute cardiac perforations associated with active fixation leads. Europace. 2009;11:206-212.
MeSH terms