Economic and Environmental Impact of Single-use Plastics at a Large Ophthalmology Outpatient Service
- PMID: 32910012
- DOI: 10.1097/IJG.0000000000001655
Economic and Environmental Impact of Single-use Plastics at a Large Ophthalmology Outpatient Service
Abstract
PRéCIS:: The use of disposable tonometer prisms and gonioscopy lenses at a large ophthalmology outpatient service incurs significant financial and environmental waste that may not be justified given the limited data surrounding arguments for their use.
Purpose: To quantify the economic and environmental burden of single-use plastics from an ophthalmology outpatient service at a large tertiary hospital and describe the relative value and evidence for the safety of disposable versus nondisposable tonometer prisms and gonioscopy lenses.
Methods: The total number of single-use applanation tonometer prisms and gonioscopy lenses used per year at Boston Medical Center (BMC) was estimated, and the average dollars spent and plastic waste generated in kilograms per year were then determined. These values were compared with the total spending and waste that would be produced if the clinic were to use nondisposable tonometer prisms and gonioscopy lenses exclusively.
Results: Single-use tonometer prisms cost an average of $70,282 per year and produce ~100.8 kg of plastic waste per year at BMC. Single-use gonioscopy lenses cost ~$9,040 per year and produce 8.8 kg of plastic waste per year at BMC. An excess of $65,185 and 109.6 kg of plastic waste could be avoided each year by only using nondisposable tonometer prisms and gonioscopy lenses at the BMC ophthalmology outpatient service.
Conclusions: Single-use plastics in ophthalmology outpatient services generate significant environmental waste and financial cost compared with nondisposable instruments. This cost may outweigh the benefits of these instruments given the limited data surrounding arguments for their use.
Similar articles
-
Reliability of tonosafe disposable tonometer prisms: clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study.Eye (Lond). 2011 May;25(5):651-6. doi: 10.1038/eye.2011.40. Epub 2011 Apr 1. Eye (Lond). 2011. PMID: 21455241 Free PMC article.
-
[Effectivity of different methods for disinfection of applanation tonometer prisms (author's transl)].Ophthalmologica. 1980;181(1):13-22. doi: 10.1159/000309020. Ophthalmologica. 1980. PMID: 7207970 German.
-
[Disinfection of plastic objects used with Goldmann's applanation tonometer].Ophthalmologica. 1971;162(3):129-39. doi: 10.1159/000306254. Ophthalmologica. 1971. PMID: 4996833 German. No abstract available.
-
Disinfection of Tonometers: A Report by the American Academy of Ophthalmology.Ophthalmology. 2017 Dec;124(12):1867-1875. doi: 10.1016/j.ophtha.2017.05.033. Epub 2017 Jul 11. Ophthalmology. 2017. PMID: 28705429 Review.
-
Sterilisation of tonometers and gonioscopes.Indian J Ophthalmol. 1998 Jun;46(2):113-6. Indian J Ophthalmol. 1998. PMID: 9847488 Review.
Cited by
-
Evaluation of laser power stability of repeatedly used SubCyclo probe in micropulse transscleral cyclophotocoagulation for glaucoma: A step towards sustainable ophthalmic surgery.PLoS One. 2023 Dec 8;18(12):e0295517. doi: 10.1371/journal.pone.0295517. eCollection 2023. PLoS One. 2023. PMID: 38064479 Free PMC article.
-
Waste audits in healthcare: A systematic review and description of best practices.Waste Manag Res. 2023 Jan;41(1):3-17. doi: 10.1177/0734242X221101531. Epub 2022 Jun 2. Waste Manag Res. 2023. PMID: 35652693 Free PMC article.
-
A mixed-methods analysis of the climate impact, acceptability, feasibility and cost of switching from single-use pulp to reusable plastic trays in a large NHS trust.Future Healthc J. 2023 Jul;10(2):157-160. doi: 10.7861/fhj.2022-0129. Future Healthc J. 2023. PMID: 37786636 Free PMC article.
-
Sustainability and minimization of carbon footprint in ophthalmology: what can we change in the outpatient clinic routine?Eye (Lond). 2025 Aug;39(12):2363-2368. doi: 10.1038/s41433-025-03885-0. Epub 2025 Jun 18. Eye (Lond). 2025. PMID: 40533547 Free PMC article. Review.
-
Alcohol wipes are the most justifiably sustainable disinfection method for Goldmann tonometry.Eye (Lond). 2025 Jul;39(10):1896-1900. doi: 10.1038/s41433-025-03855-6. Epub 2025 May 20. Eye (Lond). 2025. PMID: 40394264 Free PMC article. Review.
References
-
- Eckelman MJ, Sherman J. Environmental impacts of the U.S. Health Care System and effects on public health. PLoS One. 2016;11:e0157014.
-
- Mamalis N. Reducing the environmental impact of cataract surgery: Sustainability versus safety: a tradeoff? J Cataract Refract Surg. 2018;44:1–2.
-
- Venkatesh R, van Landingham SW, Khodifad AM, et al. Carbon footprint and cost-effectiveness of cataract surgery. Curr Opin Ophthalmol. 2016;27:82–88.
-
- Jasani KM, Putri C, Pearl A, et al. Disposable versus non-disposable tonometer prisms: a UK national survey. BMJ Open Ophthalmol. 2017;1:e000019.
-
- Colon LE. Keratoconjunctivitis due to adenovirus type 8: report on a large outbreak. Ann Ophthalmol. 1991;23:63–65.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources