Abstract
Background: MR arthrography (MRA) is commonly used in the assessment of shoulder internal derangements. Correct intra-articular contrast injection is required for this modality. Anterior injections under fluoroscopic, ultrasound-guidance, or without image-guidance have been described in the literature. However, no simultaneous comparison has been performed between the three techniques.
Purpose: To compare the accuracy and performance of fluoroscopy (FL)-guided, ultrasound (US)-guided and non-image-guided intra-articular contrast injection via an anterior approach for performing shoulder MRA.
Study type: Prospective.
Subjects: Two-hundred and ten patients (180 men and 30 women; mean age, 33 ± 12 years; range 20-60 years) with clinically suspected shoulder pathology.
Field strength/sequence: 1.5T/fat-suppressed T1 -weighted, T2 -weighted, and 3D-gradient-echo images.
Assessment: Patients underwent shoulder MRA after anterior intra-articular contrast injection under FL- or US-guidance or without image-guidance. Patients were randomized among the three techniques with each group comprising 70. The techniques were compared according to the accuracy of intra-articular needle placement, attempts success rate, pain during and 24 hours after injection, procedure times, contrast extravasation rate, joint distension, and MRA diagnostic efficacy. Pain was assessed by the visual analog scale (VAS) pain-score.
Statistical tests: Pearson's chi-squared and Kruskal-Wallis tests.
Results: FL- and US-guided injections (100% accuracy) were significantly more accurate than non-image-guided (85.7% accuracy) (P < 0.05). US-guidance was the least painful, with statistical differences between image-guided and non-image-guided techniques regarding the first attempt success rate (95.7% and 92.8% for FL- and US-guided vs. 78.6% for blinded), VAS-score 24 hours-post-procedure (1.7 ± 1.7, and 1.5 ± 1.4 vs. 2.2 ± 1.4), procedure time (11.9 ± 1.6, and 7.4 ± 1.7 vs. 4.3 ± 0.76 minutes), and contrast extravasation rate (5.7%, and 8.6% vs. 30%) (all P < 0.05). Procedure time was also significantly different between FL and US-guidance (P < 0.05).
Data conclusion: Imaging-guided injections are more accurate and tolerable than non-image-guided and should be considered to confirm intra-articular needle position, hence adequate capsular distension and good diagnostic quality of shoulder MRA. US guidance is a less painful, rapid, and safe alternative to the FL approach. Evidence Level: 2 Technical Efficacy Stage: 5. J. MAGN. RESON. IMAGING 2021;53:481-490.
Keywords: fluoroscopy; non-image-guided; shoulder MRA; ultrasound.
© 2020 International Society for Magnetic Resonance in Medicine.
Similar articles
-
Ultrasound-guided interventions of the upper extremity joints.Skeletal Radiol. 2023 May;52(5):897-909. doi: 10.1007/s00256-022-04148-9. Epub 2022 Aug 13. Skeletal Radiol. 2023. PMID: 35962837 Free PMC article. Review.
-
Radio-carpal wrist MR arthrography: comparison of ultrasound with fluoroscopy and palpation-guided injections.Skeletal Radiol. 2022 Apr;51(4):765-775. doi: 10.1007/s00256-021-03845-1. Epub 2021 Jul 29. Skeletal Radiol. 2022. PMID: 34324016 Clinical Trial.
-
[Ultrasound-guided intraarticular injection for MR arthrography of the shoulder].Rofo. 2010 Mar;182(3):267-73. doi: 10.1055/s-0028-1109838. Epub 2009 Nov 25. Rofo. 2010. PMID: 19941245 German.
-
Shoulder magnetic resonance arthrography: a prospective randomized study of anterior and posterior ultrasonography-guided contrast injections.Acta Radiol. 2008 Oct;49(8):912-7. doi: 10.1080/02841850802203585. Acta Radiol. 2008. PMID: 18608021 Clinical Trial.
-
Ultrasound-guided joint injections for MR arthrography in pediatric patients: how we do it.Pediatr Radiol. 2015 Mar;45(3):308-16; quiz 305-7. doi: 10.1007/s00247-014-3212-9. Epub 2015 Mar 1. Pediatr Radiol. 2015. PMID: 25726013 Review.
Cited by
-
Fluoroscopy-guided injections of the upper extremity: pearls and pitfalls.Skeletal Radiol. 2023 May;52(5):843-854. doi: 10.1007/s00256-022-04129-y. Epub 2022 Jul 22. Skeletal Radiol. 2023. PMID: 35869326 Review.
-
Ultrasound-guided injection through the rotator cuff interval: a clinical perspective of one institution's results and description of technique.J Osteopath Med. 2023 Aug 18;123(12):571-576. doi: 10.1515/jom-2023-0129. eCollection 2023 Dec 1. J Osteopath Med. 2023. PMID: 37589664
-
Frequency of technical success of ultrasound-guided arthrogram injections in children.Pediatr Radiol. 2023 Nov;53(12):2380-2385. doi: 10.1007/s00247-023-05777-5. Epub 2023 Sep 29. Pediatr Radiol. 2023. PMID: 37773443
-
Ultrasound-guided interventions of the upper extremity joints.Skeletal Radiol. 2023 May;52(5):897-909. doi: 10.1007/s00256-022-04148-9. Epub 2022 Aug 13. Skeletal Radiol. 2023. PMID: 35962837 Free PMC article. Review.
References
-
- Bencardino JT, Beltran J, Rosenberg ZS, et al. Superior labrum anterior-posterior lesions: Diagnosis with MR arthrography of the shoulder. Radiology 2000;214(1):267-271.
-
- De Jesus JO, Parker L, Frangos AJ, Nazarian LN. Accuracy of MRI, MR arthrography, and ultrasound in the diagnosis of rotator cuff tears: A meta-analysis. Am J Roentgenol 2009;192(6):1701-1707.
-
- Fotiadou A, Drevelegas A, Nasuto M, Guglielmi G. Diagnostic performance of magnetic resonance arthrography of the shoulder in the evaluation of anteroinferior labrum abnormalities: A prospective study. Insights Imaging 2013;4(2):157-162.
-
- Schaeffeler C, Waldt S, Holzapfel K, et al. Lesions of the biceps pulley: Diagnostic accuracy of MR arthrography of the shoulder and evaluation of previously described and new diagnostic signs. Radiology 2012;264(2):504-513.
-
- Dépelteau H, Bureau NJ, Cardinal E, Aubin B, Brassard P. Arthrography of the shoulder: A simple fluoroscopically guided approach for targeting the rotator cuff interval. Am J Roentgenol 2004;182(2):329-332.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources