Clinical effect of the high insertion torque on dental implants: A systematic review and meta-analysis
- PMID: 32917400
- DOI: 10.1016/j.prosdent.2020.06.012
Clinical effect of the high insertion torque on dental implants: A systematic review and meta-analysis
Abstract
Statement of problem: A consensus on the clinical performance in dental implants placed with different insertion torques is lacking.
Purpose: The purpose of this systematic review and meta-analysis was to evaluate the effect of high insertion torque compared with regular or low torques during dental implant placement in terms of implant survival rate and marginal bone loss.
Material and methods: Two independent reviewers searched electronic databases for studies published until April 2019. The population, intervention, comparison, outcome (PICO) question was "Do patients who receive implants with a high torque (equal or higher than 50 Ncm) show similar implant survival rates and marginal bone loss as compared with those who receive implants with a regular or low torque (less than 50 Ncm)?". The meta-analysis was based on the Mantel-Haenszel (MH) and the inverse variance (IV) methods (α=.05).
Results: The search yielded 6 articles, which included 389 patients (mean age: 55.28 years) who had received 651 dental implants (437 with high torque and 214 with low or regular torque). Most studies evaluated delayed loading, except 1 study that evaluated immediate implant loading (n=50 for each group). Low or regular insertion torque had a high failure rate (4.2%) compared with high insertion torque (1.1%), chiefly because of immediate loading. However, the meta-analysis indicated no significant difference between high- and regular- or low-torque implant placement in implant survival rate (P=.52, risk ratio [RR]: 0.51, 95% confidence interval [CI]: 0.06-4.06) and marginal bone loss (P=.30, mean difference [MD]: 0.15, 95% CI: -0.14 to 0.44).
Conclusions: A high insertion torque during implant placement does not affect implant survival rate or marginal bone loss. However, further research is recommended to reassess this clinical performance.
Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Comment in
-
LIMITED EVIDENCE SUGGESTS NO CORRELATION BETWEEN IMPLANT INSERTION TORQUE AND IMPLANT SURVIVAL AND MARGINAL BONE LOSS.J Evid Based Dent Pract. 2023 Jun;23(2):101839. doi: 10.1016/j.jebdp.2023.101839. Epub 2023 Feb 8. J Evid Based Dent Pract. 2023. PMID: 37201976
Similar articles
-
The influence of insertion torque values on the failure and complication rates of dental implants: A systematic review and meta-analysis.Clin Implant Dent Relat Res. 2021 Jun;23(3):341-360. doi: 10.1111/cid.12993. Epub 2021 Mar 25. Clin Implant Dent Relat Res. 2021. PMID: 33764648
-
The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study.Int J Oral Maxillofac Implants. 2017 Jul/Aug;32(4):849-857. doi: 10.11607/jomi.5889. Int J Oral Maxillofac Implants. 2017. PMID: 28708918
-
Immediate loading of post-extractive versus delayed placed single implants in the anterior maxilla: outcome of a pragmatic multicenter randomised controlled trial 1-year after loading.Eur J Oral Implantol. 2015 Winter;8(4):347-58. Eur J Oral Implantol. 2015. PMID: 26669545 Clinical Trial.
-
Immediate non-occlusal loading of immediate post-extractive versus delayed placement of single implants in preserved sockets of the anterior maxilla: 1-year post-loading outcome of a randomised controlled trial.Eur J Oral Implantol. 2015 Winter;8(4):361-72. Eur J Oral Implantol. 2015. PMID: 26669546 Clinical Trial.
-
A clinical comparison of 1-piece versus 2-piece implants: A systematic review and meta-analysis.J Prosthet Dent. 2020 Oct;124(4):439-445. doi: 10.1016/j.prosdent.2019.08.002. Epub 2019 Dec 18. J Prosthet Dent. 2020. PMID: 31862146
Cited by
-
Three-dimensional finite element analysis of the biomechanical behaviour of different dental implants under immediate loading during three masticatory cycles.Heliyon. 2024 Jun 6;10(11):e32616. doi: 10.1016/j.heliyon.2024.e32616. eCollection 2024 Jun 15. Heliyon. 2024. PMID: 38961961 Free PMC article.
-
The Influence of Insertion Torque on Stress Distribution in Peri-Implant Bones Around Ultra-Short Implants: An FEA Study.J Funct Biomater. 2025 Jul 14;16(7):260. doi: 10.3390/jfb16070260. J Funct Biomater. 2025. PMID: 40710474 Free PMC article.
-
Influence of low insertion torque values on survival rate of immediately loaded dental implants: A systematic review and meta-analysis.J Clin Periodontol. 2023 Feb;50(2):158-169. doi: 10.1111/jcpe.13733. Epub 2022 Oct 22. J Clin Periodontol. 2023. PMID: 36217696 Free PMC article.
-
Initial Development of an Immediate Implantation Model in Rats and Assessing the Prognostic Impact of Periodontitis on Immediate Implantation.Bioengineering (Basel). 2023 Jul 28;10(8):896. doi: 10.3390/bioengineering10080896. Bioengineering (Basel). 2023. PMID: 37627781 Free PMC article.
-
High Insertion Torque-Clinical Implications and Drawbacks: A Scoping Review.Medicina (Kaunas). 2025 Jun 30;61(7):1187. doi: 10.3390/medicina61071187. Medicina (Kaunas). 2025. PMID: 40731817 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous