Intraosseous Anesthesia Using Dynamic Navigation Technology
- PMID: 32919987
- DOI: 10.1016/j.joen.2020.09.001
Intraosseous Anesthesia Using Dynamic Navigation Technology
Abstract
Introduction: This study presents a novel method to deliver intraosseous anesthesia using dynamic navigation technology. The study aimed to evaluate its safety and 3-dimensional (3D) accuracy in comparison to traditional freehand injection of intraosseous anesthesia.
Methods: Six identical sets of 3D-printed surgical jaw models (TrueJaw; DELendo, Santa Barbara, CA) comprising simulated alveolar and dental anatomy with 54 interradicular sites were used in this study. The injection sites were equally distributed based on the range of the inter-radicular distance (ie, 1.5-2.5 mm, 2.5-3.5 mm, and 3.5-4.5 mm). A board-certified endodontist randomly completed intraosseous drilling at inter-radicular sites of varying distance using freehand technique and the Navident dynamic navigation system (ClaroNav, Toronto, Ontario, Canada) with the X-Tip system (Dentsply Sirona, York, PA). The rate of root perforation associated with inter-radicular distance was compared between the 2 groups using the Fisher exact test. Two-dimensional (2D) and 3D horizontal, vertical, and angulation discrepancies between the planned and dynamically navigated guide sleeves were digitally measured using superimposed cone-beam computed tomographic scans. Analysis of variance models were used to determine if the interdental distance was associated with the accuracy measures from the dynamic navigation system. The significance level was set at 0.05.
Results: The rate of root perforation was significantly higher for the freehand group than the dynamic navigation (22% vs 0%, P < .05). For dynamic navigation, the 2D entry deviation was 0.71 mm (95% confidence interval [CI], 0.56-0.87). The mean 2D horizontal deviation was 0.96 mm (95% CI, 0.79-1.14), and the mean 2D vertical deviation was 0.70 mm (95% CI, 0.55-0.84). The 3D deviation at the tip was on an average 1.23 mm (95% CI, 1.05-1.42). The overall 3D angular deviation was on average 1.36° (95% CI, 1.15-1.56). The inter-radicular distance was not significantly associated with any 2D or 3D discrepancies.
Conclusions: Successful and accurate drilling of dynamically navigated intraosseous delivery occurred in 100% of injection sites irrespective of the inter-radicular distance. It was significantly safer in comparison to freehand intraosseous drilling to prevent injury of the roots of the adjacent teeth in close proximity.
Keywords: Dynamic navigation; Navident; guided anesthesia; guided endodontics; intraosseous anesthesia.
Published by Elsevier Inc.
Similar articles
-
3-Dimensional Accuracy of Dynamic Navigation Technology in Locating Calcified Canals.J Endod. 2020 Jun;46(6):839-845. doi: 10.1016/j.joen.2020.03.014. Epub 2020 Apr 25. J Endod. 2020. PMID: 32340763
-
Dynamic navigation: a laboratory study on the accuracy and potential use of guided root canal treatment.Int Endod J. 2021 Sep;54(9):1659-1667. doi: 10.1111/iej.13563. Epub 2021 Jun 12. Int Endod J. 2021. PMID: 33991122
-
Dynamic navigation for dental implant placement in single-tooth gaps: A preclinical pilot investigation.J Dent. 2022 Oct;125:104265. doi: 10.1016/j.jdent.2022.104265. Epub 2022 Aug 20. J Dent. 2022. PMID: 35995082
-
Dynamically Navigated versus Freehand Access Cavity Preparation: A Comparative Study on Substance Loss Using Simulated Calcified Canals.J Endod. 2020 Nov;46(11):1745-1751. doi: 10.1016/j.joen.2020.07.032. Epub 2020 Aug 11. J Endod. 2020. PMID: 32795551
-
Dynamic Navigation for Surgical Implant Placement: Overview of Technology, Key Concepts, and a Case Report.Compend Contin Educ Dent. 2018 Oct;39(9):614-621; quiz 622. Compend Contin Educ Dent. 2018. PMID: 30299111 Review.
Cited by
-
Current Applications of Dynamic Navigation System in Endodontics: A Scoping Review.Eur J Dent. 2023 Jul;17(3):569-586. doi: 10.1055/s-0042-1749361. Epub 2022 Aug 31. Eur J Dent. 2023. PMID: 36044911 Free PMC article.
-
Dynamic navigation in endodontics: A comprehensive literature review.J Conserv Dent Endod. 2024 Dec;27(12):1202-1210. doi: 10.4103/JCDE.JCDE_551_24. Epub 2024 Dec 10. J Conserv Dent Endod. 2024. PMID: 39959018 Free PMC article. Review.
-
Expert consensus on digital guided therapy for endodontic diseases.Int J Oral Sci. 2023 Dec 6;15(1):54. doi: 10.1038/s41368-023-00261-0. Int J Oral Sci. 2023. PMID: 38052782 Free PMC article. Review.
-
The learning curve of a dynamic navigation system used in endodontic apical surgery.J Dent Sci. 2024 Oct;19(4):2247-2255. doi: 10.1016/j.jds.2024.02.016. Epub 2024 Mar 1. J Dent Sci. 2024. PMID: 39347078 Free PMC article.
-
Impact of Clinician Experience on Intraosseous Anesthesia Outcomes in Endodontic Treatment: Retrospective Cohort Study.Dent J (Basel). 2025 May 27;13(6):238. doi: 10.3390/dj13060238. Dent J (Basel). 2025. PMID: 40559141 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources