Multi-domain convolutional neural network (MD-CNN) for radial reconstruction of dynamic cardiac MRI

Affiliations
Free article

Multi-domain convolutional neural network (MD-CNN) for radial reconstruction of dynamic cardiac MRI

Hossam El-Rewaidy et al. Magn Reson Med. 2021 Mar.
Free article

Abstract

Purpose: Cardiac MR cine imaging allows accurate and reproducible assessment of cardiac function. However, its long scan time not only limits the spatial and temporal resolutions but is challenging in patients with breath-holding difficulty or non-sinus rhythms. To reduce scan time, we propose a multi-domain convolutional neural network (MD-CNN) for fast reconstruction of highly undersampled radial cine images.

Methods: MD-CNN is a complex-valued network that processes MR data in k-space and image domains via k-space interpolation and image-domain subnetworks for residual artifact suppression. MD-CNN exploits spatio-temporal correlations across timeframes and multi-coil redundancies to enable high acceleration. Radial cine data were prospectively collected in 108 subjects (50 ± 17 y, 72 males) using retrospective-gated acquisition with 80%:20% split for training/testing. Images were reconstructed by MD-CNN and k-t Radial Sparse-Sense(kt-RASPS) using an undersampled dataset (14 of 196 acquired views; relative acceleration rate = 14). MD-CNN images were evaluated quantitatively using mean-squared-error (MSE) and structural similarity index (SSIM) relative to reference images, and qualitatively by three independent readers for left ventricular (LV) border sharpness and temporal fidelity using 5-point Likert-scale (1-non-diagnostic, 2-poor, 3-fair, 4-good, and 5-excellent).

Results: MD-CNN showed improved MSE and SSIM compared to kt-RASPS (0.11 ± 0.10 vs. 0.61 ± 0.51, and 0.87 ± 0.07 vs. 0.72 ± 0.07, respectively; P < .01). Qualitatively, MD-CCN significantly outperformed kt-RASPS in LV border sharpness (3.87 ± 0.66 vs. 2.71 ± 0.58 at end-diastole, and 3.57 ± 0.6 vs. 2.56 ± 0.6 at end-systole, respectively; P < .01) and temporal fidelity (3.27 ± 0.65 vs. 2.59 ± 0.59; P < .01).

Conclusion: MD-CNN reduces the scan time of cine imaging by a factor of 23.3 and provides superior image quality compared to kt-RASPS.

Keywords: Cardiac MRI; deep learning; image reconstruction; non-cartesian acquisition; radial acquisition; real-time imaging.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. American College of Cardiology Foundation Task Force on Expert Consensus Documents; Hundley WG, Bluemke DA, et al. ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: A report of the american college of cardiology foundation task force on expert consensus documents. Circulation. 2010;121:2462-2508.
    1. Rehwald WG, Kim RJ, Simonetti OP, Laub G, Judd RM. Theory of high-speed MR imaging of the human heart with the selective line acquisition mode. Radiology. 2001;220:540-547.
    1. Song HK, Dougherty L. k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI. Magn Reson Med. 2000;44:825-832.
    1. McGibney G, Smith MR, Nichols ST, Crawley A. Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med. 1993;30:51-59.
    1. Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med. 2008;59:771-778.

Publication types