Effects of Positive End-Expiratory Pressure in "High Compliance" Severe Acute Respiratory Syndrome Coronavirus 2 Acute Respiratory Distress Syndrome
- PMID: 32932346
- DOI: 10.1097/CCM.0000000000004640
Effects of Positive End-Expiratory Pressure in "High Compliance" Severe Acute Respiratory Syndrome Coronavirus 2 Acute Respiratory Distress Syndrome
Abstract
Objectives: Clinical observation suggests that early acute respiratory distress syndrome induced by the severe acute respiratory syndrome coronavirus 2 may be "atypical" due to a discrepancy between a relatively unaffected static respiratory system compliance and a significant hypoxemia. This would imply an "atypical" response to the positive end-expiratory pressure.
Design: Single-center, unblinded, crossover study.
Setting: ICU of Bari Policlinico Academic Hospital (Italy), dedicated to care patients with confirmed diagnosis of novel coronavirus disease 2019.
Patients: Eight patients with early severe acute respiratory syndrome coronavirus 2 acute respiratory distress syndrome and static respiratory compliance higher than or equal to 50 mL/cm H2O.
Interventions: We compared a "lower" and a "higher" positive end-expiratory pressure approach, respectively, according to the intervention arms of the acute respiratory distress syndrome network and the positive end-expiratory pressure setting in adults with acute respiratory distress syndrome studies.
Measurements and main results: Patients were ventilated with the acute respiratory distress syndrome network and, subsequently, with the ExPress protocol. After 1 hour of ventilation, for each protocol, we recorded arterial blood gas, respiratory mechanics, alveolar recruitment, and hemodynamic variables. Comparisons were performed with analysis of variance for repeated measures or Friedman test as appropriate. Positive end-expiratory pressure was increased from 9 ± 3.5 to 17.7 ± 1.7 cm H2O (p < 0.01). Alveolar recruitment was 450 ± 111 mL. Static respiratory system compliance decreased from 58.3 ± 7.6 mL/cm H2O to 47.4 ± 14.5 mL/cm H2O (p = 0.018) and the "stress index" increased from 0.97 ± 0.03 to 1.22 ± 0.07 (p < 0.001). The PaO2/FIO2 ratio increased from 131 ± 22 to 207 ± 41 (p < 0.001), and the PaCO2 increased from 45.9 ± 12.7 to 49.8 ± 13.2 mm Hg (p < 0.001). The cardiac index went from 3.6 ± 0.4 to 2.9 ± 0.6 L/min/m (p = 0.01).
Conclusions: Our data suggest that the "higher" positive end-expiratory pressure approach in patients with severe acute respiratory syndrome coronavirus 2 acute respiratory distress syndrome and high compliance improves oxygenation and lung aeration but may result in alveolar hyperinflation and hemodynamic alterations.
Comment in
-
Positive End-Expiratory Pressure in Coronavirus Disease 2019 Acute Respiratory Distress Syndrome: Higher May Be Too High.Crit Care Med. 2020 Dec;48(12):1925-1927. doi: 10.1097/CCM.0000000000004648. Crit Care Med. 2020. PMID: 33255120 No abstract available.
References
-
- Ranieri VM, Rubenfeld GD, Thompson BT, et al. Acute respiratory distress syndrome: The Berlin definition. JAMA. 2012;307:2526–33.
-
- Marini JJ, Gattinoni L. Management of COVID-19 respiratory distress. JAMA. 2020;7:435–44.
-
- Brower RG, Matthay MA, Morris A, et al. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301–8.
-
- Mercat A, Richard JC, Vielle B, et al.; Expiratory Pressure (Express) Study Group: Positive end-expiratory pressure setting in adults with acute lung injury and acute respiratory distress syndrome: A randomized controlled trial. JAMA. 2008;299:646–655.
-
- Grasso S, Terragni P, Mascia L, et al. Airway pressure-time curve profile (stress index) detects tidal recruitment/hyperinflation in experimental acute lung injury. Crit Care Med. 2004;32:1018–1027.