Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations
- PMID: 32937750
- PMCID: PMC7559075
- DOI: 10.3390/vision4030041
Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations
Abstract
Tilt and decentration of intraocular lenses (IOL) may occur secondary to a complicated cataract surgery or following an uneventful phacoemulsification. Although up to 2-3° tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance and subsequently, the patients' satisfaction. This negative impact does not affect various types of IOLs equally. In this paper we review the methods of measuring IOL tilt and decentration and focus on the effect of IOL tilt and decentration on visual function, in particular visual acuity, dysphotopsia, and wavefront aberrations. Our review found that the methods to measure the IOL displacement have significantly evolved and the available studies have employed different methods in their measurement, while comparability of these methods is questionable. There has been no universal reference point and axis to measure the IOL displacement between different studies. A remarkably high variety and brands of IOLs are used in various studies and occasionally, opposite results are noticed when two different brands of a same design were compared against another IOL design in two studies. We conclude that <5° of inferotemporal tilt is common in both crystalline lenses and IOLs with a correlation between pre- and postoperative lens tilt. IOL tilt has been noticed more frequently with scleral fixated compared with in-the-bag IOLs. IOL decentration has a greater impact than tilt on reduction of visual acuity. There was no correlation between IOL tilt and decentration and dysphotopsia. The advantages of aspheric IOLs are lost when decentration is >0.5 mm. The effect of IOL displacement on visual function is more pronounced in aberration correcting IOLs compared to spherical and standard non-aberration correcting aspherical IOLs and in multifocal versus monofocal IOLs. Internal coma has been frequently associated with IOL tilt and decentration, and this increases with pupil size. There is no correlation between spherical aberration and IOL tilt or decentration. Although IOL tilt produces significant impact on visual outcome in toric IOLs, these lenses are more sensitive to rotation compared to tilt.
Keywords: decentration; dysphotopsia; intraocular lens; tilt; visual acuity; wavefront aberration.
Conflict of interest statement
None of the authors have any financial interest in any products or procedures mentioned in this study. Other disclosures are as below: MAN: Research grants from Alcon Laboratories, USA; European Society of Cataract & Refractive Surgery; Johnson & Johnson, USA; NuVision Biotherapies, UK; Rayner Intraocular lenses, UK. Lecture fees from Alcon Laboratories, USA. Consultant to Hoya. Travel grant from Alcon Laboratories, USA & Bausch & Lomb, USA.
Similar articles
-
[Comparative study of the tilt, decentration and higher-order aberrations (HOA) of single-piece and 3-piece tecnis aspheric intraocular lenses].Zhonghua Yan Ke Za Zhi. 2015 Apr;51(4):270-5. Zhonghua Yan Ke Za Zhi. 2015. PMID: 26081230 Clinical Trial. Chinese.
-
Tilt and decentration of spherical and aspheric intraocular lenses: effect on higher-order aberrations.J Cataract Refract Surg. 2009 Jun;35(6):1006-12. doi: 10.1016/j.jcrs.2009.01.023. J Cataract Refract Surg. 2009. PMID: 19465285 Clinical Trial.
-
[Comparative study of decentration, tilt and visual quality after implantation of aspherical intraocular lenses].Zhonghua Yan Ke Za Zhi. 2022 Jul 11;58(7):521-528. doi: 10.3760/cma.j.cn112142-20211103-00518. Zhonghua Yan Ke Za Zhi. 2022. PMID: 35796125 Clinical Trial. Chinese.
-
Tilt and decentration with various intraocular lenses: A narrative review.World J Clin Cases. 2022 Apr 26;10(12):3639-3646. doi: 10.12998/wjcc.v10.i12.3639. World J Clin Cases. 2022. PMID: 35647149 Free PMC article. Review.
-
Intraocular lens alignment from purkinje and Scheimpflug imaging.Clin Exp Optom. 2010 Nov;93(6):400-8. doi: 10.1111/j.1444-0938.2010.00514.x. Epub 2010 Aug 25. Clin Exp Optom. 2010. PMID: 20738324 Review.
Cited by
-
Effect of decentration on the quality of vision in two aspheric posterior chamber intraocular lenses: A contralateral eye study.Indian J Ophthalmol. 2024 Apr 1;72(4):558-564. doi: 10.4103/IJO.IJO_1639_23. Epub 2024 Jan 8. Indian J Ophthalmol. 2024. PMID: 38189441 Free PMC article. Clinical Trial.
-
Comparison of Visual and Aberrometric Outcomes in Suture-Free Scleral Fixation: Three-Piece Lenses versus Carlevale Lenses.J Clin Med. 2022 Dec 26;12(1):188. doi: 10.3390/jcm12010188. J Clin Med. 2022. PMID: 36614989 Free PMC article.
-
Optical performance of a new design of a trifocal intraocular lens based on the Devil's diffractive lens.Biomed Opt Express. 2023 Apr 28;14(5):2365-2374. doi: 10.1364/BOE.487812. eCollection 2023 May 1. Biomed Opt Express. 2023. PMID: 37206145 Free PMC article.
-
Commentary: Determinants of crystalline lens tilt and decentration: Optimizing cataract surgery outcomes.Indian J Ophthalmol. 2023 Mar;71(3):769-770. doi: 10.4103/ijo.IJO_2273_22. Indian J Ophthalmol. 2023. PMID: 36872675 Free PMC article. No abstract available.
-
A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.J Clin Med. 2024 Dec 31;14(1):187. doi: 10.3390/jcm14010187. J Clin Med. 2024. PMID: 39797271 Free PMC article.
References
-
- Kimura S., Morizane Y., Shiode Y., Hirano M., Doi S., Toshima S., Fujiwara A., Shiraga F. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS ONE. 2017;12:e0184066. doi: 10.1371/journal.pone.0184066. - DOI - PMC - PubMed
Publication types
LinkOut - more resources
Full Text Sources
Other Literature Sources