Influence of Conventional or Invisalign Orthodontic Treatment on Mineral and Trace Element Salivary Levels: Longitudinal Study with Total Reflection X-ray Fluorescence
- PMID: 32946034
- DOI: 10.1007/s12011-020-02396-1
Influence of Conventional or Invisalign Orthodontic Treatment on Mineral and Trace Element Salivary Levels: Longitudinal Study with Total Reflection X-ray Fluorescence
Abstract
This work aimed to evaluate the salivary concentration of chemical elements in patients undergoing orthodontic treatment with fixed orthodontic appliances and removable aligners. Twelve Angle Class I and II orthodontic patients undergoing treatment with conventional fixed appliances and 15 patients treated with removable aligners provided unstimulated whole saliva samples before treatment (pre) and after 3 months of treatment (post). The concentration and secretion rate of chemical elements in saliva were determined by total reflection X-ray fluorescence. Differences from pre to post and between groups were determined with the paired T test or Wilcoxon test, and two-way ANOVA, considering P < 0.05. The concentrations of S, Cl, and K decreased, while Zn increased significantly (P < 0.05) between pre and post treatment with the fixed appliance treatment. The salivary secretion rate of S was decreased from pre to post in the fixed appliance group. No differences in the concentration and secretion rate of chemical elements were detected from pre to post in the Invisalign group. Fe secretion rate presented an interaction between time and treatment, with lower secretion at post (P = 0.02) in the Invisalign group. Increased Br secretion rate and decreased Rb, Fe, P, and K in Invisalign patients suggested a better salivary electrolyte profile regarding periodontal bone remodeling. No significant alterations in ions associated with metal corrosion and inflammatory reactions were detected in orthodontic patients under dental plaque control.
Keywords: Invisalign; Orthodontic treatment; Saliva; Total reflection X-ray fluorescence; Trace elements.
References
-
- Martin-Camean A, Jos A, Puerto M, Calleja A, Iglesias-Linares A, Solano E, Camean AM (2015) In vivo determination of aluminum, cobalt, chromium, copper, nickel, titanium and vanadium in oral mucosa cells from orthodontic patients with mini-implants by inductively coupled plasma-mass spectrometry (ICP-MS). J Trace Elem Med Biol 32:13–20. https://doi.org/10.1016/j.jtemb.2015.05.001 - DOI - PubMed
-
- Natarajan M, Padmanabhan S, Chitharanjan A, Narasimhan M (2011) Evaluation of the genotoxic effects of fixed appliances on oral mucosal cells and the relationship to nickel and chromium concentrations: an in-vivo study. Am J Orthod Dentofac Orthop 140(3):383–388. https://doi.org/10.1016/j.ajodo.2010.07.027 - DOI
-
- Mikulewicz M, Chojnacka K, Wozniak B, Downarowicz P (2012) Release of metal ions from orthodontic appliances: an in vitro study. Biol Trace Elem Res 146(2):272–280. https://doi.org/10.1007/s12011-011-9233- - DOI - PubMed
-
- Dwivedi A, Tikku T, Khanna R, Maurya RP, Verma G, Murthy RC (2015) Release of nickel and chromium ions in the saliva of patients with fixed orthodontic appliance: an in-vivo study. Natl J Maxillofac Surg 6(1):62–66. https://doi.org/10.4103/0975-5950.168224 - DOI - PubMed - PMC
-
- Amini F, Rahimi H, Morad G, Mollaei M (2013) The effect of stress on salivary metal ion content in orthodontic patients. Biol Trace Elem Res 155(3):339–343. https://doi.org/10.1007/s12011-013-9812-7 - DOI - PubMed
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources