Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Mar;17(1):58-63.
doi: 10.1007/s12024-020-00311-7. Epub 2020 Sep 18.

Electrical weapons and rhabdomyolysis

Affiliations

Electrical weapons and rhabdomyolysis

Mark W Kroll et al. Forensic Sci Med Pathol. 2021 Mar.

Abstract

It has been suggested that an application of a conducted electrical weapon (CEW) might cause muscle injury such as rhabdomyolysis and an acute inflammatory response. We explored this hypothesis by testing the effects of electrical weapons on circulating markers of inflammation and muscle damage. In a prospective study, 29 volunteers received a full-trunk 5-s TASER® X26(E) CEW exposure. Venous blood samples were taken before, 5 min after, and at 24 h following the discharge. We tested for changes in serum levels of C-reactive protein (CRP), alkaline phosphatase (ALP), myoglobin, albumin, globulin, albumin/globulin ratio, aspartate and alanine aminotransferase, creatine kinase, total protein, bilirubin, and lactic acid dehydrogenase. Uncorrected CRP and myoglobin levels were lower in the immediate post exposure period (CRP levels 1.44 ± 1.39 v 1.43 ± 1.32 mg/L; p = 0.046 and myoglobin 36.8 ± 11.9 v 36.1 ± 13.9 μg/L; p = 0.0019) but these changes were not significant after correction for multiple comparisons. There were no changes in other biomarkers. At 24 h, CRP levels had decreased by 30% to 1.01 ± 0.80 mg/L (p = 0.001 from baseline). ALP was unchanged immediately after the CEW application but was reduced by 5% from baseline (66.2 ± 16.1 to 62.7 ± 16.1 IU/L; p = 0.0003) at 24 h. No other biomarkers were different from baseline at 24 h. A full-trunk electrical weapon exposure did not lead to clinically significant changes in the acute phase protein levels or changes in measures of muscle cellular injury. We found no biomarker evidence of rhabdomyolysis.

Keywords: Alkaline phosphatase; C-reactive protein; CEW; Electrical weapon; Lactate dehydrogenase; Myoglobin; Rhabdomyolysis; Taser®.

PubMed Disclaimer

References

    1. Vilke GM, Chan TC. Less lethal technology: medical issues. Policing. 2007;30:341–57. - DOI
    1. White MD, Ready J. The TASER as a less lethal force alternative: findings on use and effectiveness in a large metropolitan police agency. Police Q. 2007;10:170–91. - DOI
    1. MacDonald JM, Kaminski RJ, Smith MR. The effect of less-lethal weapons on injuries in police use-of-force events. Am J Public Health. 2009;99:2268–74. - DOI
    1. Taylor B, Woods DJ. Injuries to officers and suspects in police use-of-force cases: a quasi-experimental evaluation. Police Q. 2010;13:260–89. - DOI
    1. Kroll M, Brave M, Pratt H, Witte K, Kunz S, Luceri R. Benefits, risks, and myths of TASER® handheld electrical weapons. Human Factors Mech Eng Defense Safety. 2019;3:7. - DOI

MeSH terms

LinkOut - more resources