Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2020 Sep/Oct;33(5):553-564.
doi: 10.11607/ijp.6726.

Impact of Concave/Convergent vs Parallel/ Divergent Implant Transmucosal Profiles on Hard and Soft Peri-implant Tissues: A Systematic Review with Meta-Analyses

Meta-Analysis

Impact of Concave/Convergent vs Parallel/ Divergent Implant Transmucosal Profiles on Hard and Soft Peri-implant Tissues: A Systematic Review with Meta-Analyses

Nicola Alberto Valente et al. Int J Prosthodont. 2020 Sep/Oct.

Abstract

Purpose: To systematically review the literature comparing marginal bone loss (MBL) and pink esthetic scores of implants with convergent or concave transmucosal profiles vs divergent or parallel profiles.

Materials and methods: A PICO question was defined, and an electronic search was carried out in the MEDLINE/PubMed and Cochrane Oral Health Group databases. Studies documenting type of transmucosal profile (either tissue-level profiles or abutments) and soft and/or hard tissue outcomes of implants were considered eligible. Studies were selected on the basis of the inclusion criteria and quality assessments. A meta-analysis with subgroup analyses was performed.

Results: Five papers fulfilled the inclusion criteria, and four were eligible for meta-analysis. Significantly less MBL was found in concave/convergent groups, with a mean difference of 0.772 (95% confidence interval [CI]: 0.450 to 1.095; P < .001). In the subgroup analyses for platform-switching and platform-matching connections, a significant effect in favor of concave/convergent was detected, with a standardized difference in means of 1.135 (95% CI: 0.688 to 1.583, P < .001) when platform switching was considered. No significant effects were found for platform-matching connections.

Conclusion: Within the limitations of this review, it is suggested that concave/convergent implant transmucosal profiles result in less MBL. No statistically significant results were obtained for soft tissue-related outcomes or for the platform-matching connection subgroup.

PubMed Disclaimer

Substances

LinkOut - more resources