In vitro evaluation of the modified forwarder knot used to end a continuous suture pattern in large-gauge suture
- PMID: 32959894
- DOI: 10.1111/vsu.13519
In vitro evaluation of the modified forwarder knot used to end a continuous suture pattern in large-gauge suture
Abstract
Objective: To evaluate the strength and size of forwarder end (FE) knots modified to end continuous suture lines compared with Aberdeen (AB), square (SQ), and surgeon's (SU) knots.
Study design: In vitro mechanical study.
Study population: Knotted suture.
Methods: Knots were tied with 2 USP (United States Pharmacopeia) polydioxanone, 2 USP, and 3 USP polyglactin 910 and tested on a universal testing machine under linear tension. Mode of failure and knot holding capacity (KHC) were recorded, and relative knot security (RKS) was calculated. Knot volume and weight were determined by digital micrometer and balance. Knot holding capacity, RKS, size, and weight between knot type, number of throws, and suture type and size were compared by using analysis of variance testing, with P < .05 considered significant.
Results: In all suture types and number of throws, FE knot KHC/RKS was 28% to 66.99% (1.2-1.6 fold) stronger compared with SQ/SU knots (P < .001). For 2 USP polydioxanone, FE knots had 10% (1.1 fold) higher KHC/RKS compared with AB knots (P < .042). However, in 2 and 3 USP polyglactin 910, FE knot KHC/RKS values were not different from those of AB knots (P > .080). Forwarder end/AB knots failed by suture breakage at the knot, whereas some SQ/SU knots unraveled. Forwarder end knots in 2 and 3 USP polyglactin 910 were 21.1% to 44.4% (1.2-1.4 fold) smaller compared with SQ/SU knots (P < .028). Forwarder end knots in 2 and 3 USP polyglactin 910 were 40% to 99% (1.4-2.0 fold) larger compared with AB knots (P < .001).
Conclusion: Forwarder end knots provided increased KHC/RKS compared with SQ/SU knots.
Clinical relevance: Forwarder end knots should be considered for closures when suture is placed under tension.
© 2020 The Authors. Veterinary Surgery published by Wiley Periodicals LLC on behalf of American College of Veterinary Surgeons.
Similar articles
-
In Vitro Evaluation of the Size, Knot Holding Capacity, and Knot Security of the Forwarder Knot Compared to Square and Surgeon's Knots Using Large Gauge Suture.Vet Surg. 2016 Nov;45(8):1034-1040. doi: 10.1111/vsu.12556. Epub 2016 Sep 29. Vet Surg. 2016. PMID: 27685840
-
In Vitro Evaluation of the Aberdeen Knot for Continuous Suture Patterns with Large Gauge Suture.Vet Surg. 2016 Oct;45(7):955-961. doi: 10.1111/vsu.12538. Epub 2016 Sep 8. Vet Surg. 2016. PMID: 27604910
-
Evaluation of the in vitro performance of the double forwarder knot, compared to square and surgeon's knots using large gauge suture.Vet Surg. 2024 Feb;53(2):376-383. doi: 10.1111/vsu.14058. Epub 2023 Dec 27. Vet Surg. 2024. PMID: 38151296
-
The ultimate Aberdeen knot.Ann R Coll Surg Engl. 2007 Oct;89(7):713-7. doi: 10.1308/003588407X205468. Ann R Coll Surg Engl. 2007. PMID: 17959013 Free PMC article. Review.
-
Knot Security 101: A Comprehensive Practical Review to Optimal Knot Configuration, Pulling Direction, Throw Count, and Tail Length.Plast Reconstr Surg Glob Open. 2024 Aug 9;12(8):e6047. doi: 10.1097/GOX.0000000000006047. eCollection 2024 Aug. Plast Reconstr Surg Glob Open. 2024. PMID: 39139841 Free PMC article. Review.
References
REFERENCES
-
- Wilson DA, Baker GJ, Boero MJ. Complications of celiotomy incisions in horses. Vet Surg. 1995;24:506-514.
-
- Freeman DE, Rötting AK, Inoue OJ. Abdominal closure and complications. Clin Tech Equine Pract. 2002;1(3):174-187.
-
- Magee AA, Galuppo LD. Comparison of incisional bursting strength of simple continuous and inverted cruciate suture patterns in the equine linea alba. Vet Surg. 1999;28:442-447.
-
- Anderson SL, Bracamonte JL, Hendrick S, Carmalt JL, Wilson DG. Ex vivo comparison of 7 polydioxonane, 2 polyglactin 910 for closure of ventral median celiotomy in horses. Vet Surg. 2013;42:463-467.
-
- Fierheller EE, Wilson DG. An in vitro biomechanical comparison of the breaking strength and stiffness of polydioxanone (sizes 2,7) and polyglactin 910 (sizes 3,6) in the equine linea alba. Vet Surg. 2005;34:18-23.
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources