Cardiovascular Implantable Electronic Device Surgery Following Left Ventricular Assist Device Implantation

Affiliations
Free article
Observational Study

Cardiovascular Implantable Electronic Device Surgery Following Left Ventricular Assist Device Implantation

Eric Black-Maier et al. JACC Clin Electrophysiol. 2020 Sep.
Free article

Abstract

Objectives: This study sought to determine the indications, characteristics, and outcomes of cardiovascular implantable electronic device (CIED) surgery in patients with LVAD.

Background: Many patients with a left ventricular assist device (LVAD) will require implantable cardioverter-defibrillator generator change or device revision or are candidates for de novo implantable cardioverter-defibrillator implantation following LVAD implantation.

Methods: We performed an observational retrospective study of all LVAD recipients who subsequently underwent CIED surgery at Duke University Hospital from 2009 to 2019.

Results: A total of 159 patients underwent CIED surgery following LVAD implantation, including generator change (n = 93), device revision (n = 38), and de novo implant (n = 28). The median (interquartile range) time from LVAD implantation to CIED surgery was 18.1 months (5.5 to 35.1 months). Pre-operative risk for infection was elevated in the overall cohort with a median (interquartile range) Prevention of Arrhythmia Device Infection Trial (PADIT) score of 7.0 (5.0 to 9.0). Pocket hematoma occurred in 21 patients (13.2%) following CIED surgery. Antimicrobial envelops were used in 43 patients (27%). Device infection due to CIED surgery occurred in 5 (3.1%) patients and occurred only in patients who developed post-operative pocket hematoma (p < 0.001). Mortality at 1 year following CIED surgery was 20% (n = 32).

Conclusions: CIED surgery following LVAD implantation is associated with an increased risk for pocket hematoma and CIED infection. Further studies are needed to determine the risk-benefit ratio of CIED surgery in patients with LVADs.

Keywords: implantable cardioverter defibrillator; infection; left ventricular assist device; pocket hematoma.