Radiation dose monitoring in computed tomography: Status, options and limitations

Affiliations
Review

Radiation dose monitoring in computed tomography: Status, options and limitations

Ioannis A Tsalafoutas et al. Phys Med. 2020 Nov.

Abstract

In the last few years there has been an increasing interest on radiation dose to patients undergoing various diagnostic or therapeutic procedures with the use of ionizing radiation. Especially for CT examinations and interventional procedures, where it is known that patient doses are much higher than conventional radiography, new norms have been published that require to have appropriate radiation dose indices registered in the patient medical record. Because of these demands, dose monitoring has been recommended and adopted into many clinical practices as a routine procedure for every patient and every examination. Dedicated dose monitoring systems (DMS) that facilitate data collection and processing, statistical comparisons, reporting and management of radiation dose related information have been devised and are being used worldwide. In this review paper, a brief flashback to the reasons that necessitated dose monitoring in radiology will be first presented. Furthermore, since the focus of this manuscript is on CT, the CT dosimetry principles and metrics will be summarized. The limitations of these metrics will be also discussed, so that DMS users are aware of the semantics of the parameters shown in the DMS reports. The operation of DMS systems will be outlined to make users aware of functions, limitations, and available options of DMS systems. Furthermore, the usefulness of DMS systems as an optimization tool will be presented and discussed. Finally, information about the DMS solutions available in the market and relevant links will be presented.

Keywords: CT; Dose monitoring; Radiation dose; Radiation safety.