. 2021 Mar;85(3):1441-1454.
doi: 10.1002/mrm.28527. Epub 2020 Sep 28.

Distortion-free 3D diffusion imaging of the prostate using a multishot diffusion-prepared phase-cycled acquisition and dictionary matching

Affiliations

Distortion-free 3D diffusion imaging of the prostate using a multishot diffusion-prepared phase-cycled acquisition and dictionary matching

Elisa Roccia et al. Magn Reson Med. 2021 Mar.

Abstract

Purpose: To achieve three-dimensional (3D) distortion-free apparent diffusion coefficient (ADC) maps for prostate imaging using a multishot diffusion prepared-gradient echo (msDP-GRE) sequence and ADC dictionary matching.

Methods: The msDP-GRE sequence is combined with a 3D Cartesian, centric k-space trajectory with center oversampling. Oversampled k-space center averaging and phase cycling are used to address motion- and eddy current-induced magnitude corruption. Extended-phase-graph (EPG) simulations and ADC dictionary matching are used to compensate for T1 effects. To shorten the acquisition time, each volume is undersampled by a factor of two and reconstructed using iterative sensitivity encoding. The proposed approach is characterized using simulations and validated in a kiwifruit phantom, comparing the msDP-GRE ADC maps obtained using both standard monoexponential fitting and dictionary matching with the clinical standard single-shot diffusion weighted-echo planar imaging (ssDW-EPI) ADC. Initial in vivo feasibility is tested in three healthy subjects, and geometric distortion is compared with anatomical T2 -weighted-turbo spin echo.

Results: In the kiwifruit phantom experiment, the signal magnitude could be recovered using k-space center averaging and phase cycling. No statistically significant difference was observed in the ADC values estimated using msDP-GRE with dictionary matching and clinical standard DW-EPI (P < .05). The in vivo prostate msDP-GRE scans were free of geometric distortion caused by off-resonance susceptibility, and the ADC values in the prostate were in agreement with values found in the published literature.

Conclusion: Nondistorted 3D ADC maps of the prostate can be achieved using a msDP sequence and dictionary matching.

Keywords: 3T magnetic resonance imaging; apparent diffusion coefficient mapping; dictionary matching; diffusion; prostate cancer imaging; quantitative magnetic resonance imaging.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Turkbey B, Rosenkrantz AB, Haider MA, et al. Prostate imaging reporting and data system version 2.1: 2019 Update of prostate imaging reporting and data system version 2. Eur Urol. 2019;76:340-351.
    1. Weinreb JC, Barentsz JO, Choyke PL, et al. PI-RADS prostate imaging - Reporting and data system: 2015, Version 2. Eur Urol. 2016;69:16-40.
    1. Ahmed HU, El-Shater Bosaily A, Brown LC, et al. Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): A paired validating confirmatory study. Lancet. 2017;6736:1-8.
    1. Kasivisvanathan V, Rannikko AS, Borghi M, et al. MRI-targeted or standard biopsy for prostate-cancer diagnosis. N Engl J Med. 2018;378:1767-1777.
    1. Rouvière O, Puech P, Renard-Penna R, et al. Use of prostate systematic and targeted biopsy on the basis of multiparametric MRI in biopsy-naive patients (MRI-FIRST): A prospective, multicentre, paired diagnostic study. Lancet. 2019;20:100-109.

Publication types

LinkOut - more resources