Comparative Study
. 2020 Sep 30:26:e926977.
doi: 10.12659/MSM.926977.

Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer

Affiliations
Comparative Study

Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer

Andrzej Lorek et al. Med Sci Monit. .

Abstract

BACKGROUND Contrast-enhanced spectral mammography (CESM) is digital mammography with contrast agent. This promising new breast imaging method can be used for planning surgical treatment. This study compared CESM versus digital mammography (MG) in evaluating tumor size in breast cancer. MATERIAL AND METHODS Comparison of tumor dimensions in CESM, MG, and histopathology was made. The correlation of these data was assessed by histopathological type, biological subtype, grading of the carcinoma, and patient age. RESULTS The average difference in tumor size between CESM and histopathological examination was 5 mm. The differences in size measurement between CESM and MG were significant (p=0.00). The Pearson's linear correlation coefficients of CESM versus HP and MG versus HP were -0.01 (p=0.79) and -0.25 (p=0.00), respectively, indicating no differences between CESM and HP based on the lesion size. A weak negative correlation between those values was observed on MG. No relationship was found between the tumor size in CESM and the biological subtype, carcinoma malignancy degree, or patient age. CONCLUSIONS CESM is a new diagnostic method in breast cancer. The accuracy of measurement of tumor size using CESM is independent of lesion size, but it overestimates the size by 5 mm on average. The difference is not dependent on grading, biological subtype of the carcinoma, or patient age. They concern the histopathological type, and values are significantly greater in pre‑invasive carcinomas.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest

None.

Figures

Figure 1
Figure 1
(A, B) NST GII.
Figure 2
Figure 2
(A, B) Mucinous carcinoma.
Figure 3
Figure 3
(A, B) DCIS high grade.

References

    1. International Agency for Research on Cancer. GLOBOCAN. 2018. Available from: http://globocan.iarc.fr.
    1. Wojciechowska U, Didkowska J. Polish National Cancer Registry, Oncology Center – Maria Sklodowska-Curie. http://onkologia.org.pl [in Polish]
    1. Pisano ED, Hendrick RE, Yaffe MJ, et al. Diagnostic accuracy of digital versus film mammography: Exploratory analysis of selected population subgroups in DMIST. Radiology. 2008;246:376–83. - PMC - PubMed
    1. Jochelson M. Advanced imaging techniques for the detection of breast cancer. Am Soc Clin Oncol Educ Book. 2012:65–69. - PubMed
    1. Fischer U, Baum F, Obenauer S, et al. Comparative study in patients with microcalcifications: full-field digital mammography vs. screen-film mammography. Eur Radiol. 2002;12:2679–83. - PubMed

Publication types