Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Feb;18(2):189-198.
doi: 10.1016/j.hrthm.2020.09.016. Epub 2020 Sep 30.

Mapping and ablation of clinical spontaneous perimitral atrial tachycardias using an ultra-high-resolution mapping system

Affiliations

Mapping and ablation of clinical spontaneous perimitral atrial tachycardias using an ultra-high-resolution mapping system

Shinsuke Miyazaki et al. Heart Rhythm. 2021 Feb.

Abstract

Background: Perimitral atrial tachycardias (PMATs) are common atrial tachycardias (ATs), yet their mechanisms vary.

Objective: The purpose of this study was to characterize clinical spontaneous PMATs using an ultra-high-resolution (UHR) mapping system.

Methods: The study included 32 consecutive PMATs in 31 patients who had undergone AT mapping/ablation using a UHR mapping system.

Results: Six, 10, 11, and 5 PMATs occurred in cardiac intervention-naïve (group A), post-lateral/posterior mitral isthmus linear ablation (group B), post-atrial fibrillation ablation without mitral isthmus linear ablation (group C), and post-cardiac surgery (group D) patients, respectively. Group A patients tended to be older, more likely were female, and had sinus node or atrioventricular conduction disturbances more frequently. A 12-lead synchronous isoelectric interval was observed in 15 PMATs (46.9%). Coronary sinus activation was proximal to distal or distal to proximal except in 3 PMATs with straight patterns due to epicardial gaps. Left atrial anterior/septal wall (LAASW) low-voltage areas were smallest in group B. Slow conduction areas (SCAs) were identified in 26 PMATs (81.2%) and were located on the LAASW in all group A and group D patients. Conduction velocity in the SCAs was slowest in group B. In group B, all PMATs were terminated by single applications, and the gaps were located epicardially in 5 of 10 (50%). Anterior (n = 23) or lateral/posterior (n = 9) mitral isthmus linear block was successfully created without any complications in all. Twenty-five concomitant ATs among 18 patients (58.1%) also were eliminated. During a median of 20.0 (11.0-40.0) months of follow-up, 28 patients (90.3%) were free from any atrial tachyarrhythmias.

Conclusion: An UHR mapping-guided approach with identification of the individual tachycardia mechanism should be the preferred strategy given the distinct and complex arrhythmia mechanisms.

Keywords: Atrial tachycardia; Catheter ablation; Mitral isthmus; Perimitral atrial tachycardia; Ultra–high-resolution mapping.