Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan-Feb;62(1):57-64.
doi: 10.1016/j.hjc.2020.09.011. Epub 2020 Sep 29.

Outcomes of transfemoral transcatheter aortic valve implantation (TAVI) and predictors of thirty-day major adverse cardiovascular events (MACE) and one-year mortality

Affiliations
Free article

Outcomes of transfemoral transcatheter aortic valve implantation (TAVI) and predictors of thirty-day major adverse cardiovascular events (MACE) and one-year mortality

Christos Eftychiou et al. Hellenic J Cardiol. 2021 Jan-Feb.
Free article

Abstract

Objective: TAVI is more frequently used to treat aortic stenosis with the mandate to have a low as possible rate of adverse events. We present our 30-day outcomes and one-year mortality and examine the factors associated with them.

Methods: A prospective evaluation was performed of all patients who underwent transfemoral TAVI in Nicosia General Hospital from January 2015 until March 2020. MACE were defined as cardiac death, disabling stroke, and/or major vascular complications (VC). Multiple logistic and Cox regression analyses were used to identify the factors associated with 30-day MACE and one-year mortality, respectively.

Results: A total of 235 TAVI procedures were performed (178 balloon-expandable, 57 self-expandable). Thirty-day outcomes were MACE: 4.3%, cardiovascular death: 2.1%, disabling stroke: 1.3%, major VC: 1.7%, and contrast induced nephropathy (CIN): 4.3%. There was a rate of 6.2% new pacemaker implantations and 0.9% of more than mild aortic valve regurgitation (AR) at 30 days. Mortality at one year was 15.1%. The balloon-expandable valves appear to have less new pacemakers, less mild AR, lower contrast volume used, and less days of hospitalization, while the self-expandable valves have lower post-procedural gradients. Low hemoglobulin, history of atrial fibrillation (AF), and lower BMI were predictors of 30-day MACE. Serum creatinine >2 mg/dL, history of AF, RVSP >60 mmHg and major VC are predictors of one-year mortality.

Conclusion: We have shown excellent 30-day results with low incidence of adverse events for both the balloon-expandable and self-expandable valves. Clinical factors are the main predictors of both 30-day MACE and one-year mortality; major VC is a strong predictor of one-year mortality.

Keywords: TAVI MACE; TAVI outcomes; TAVI survival; Transcatheter Aortic Valve Implantation.

PubMed Disclaimer

MeSH terms

LinkOut - more resources