Resuscitative endovascular balloon occlusion of the aorta-Interest is widespread but need for training persists
- PMID: 33009200
- PMCID: PMC7830710
- DOI: 10.1097/TA.0000000000002855
Resuscitative endovascular balloon occlusion of the aorta-Interest is widespread but need for training persists
Abstract
Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) was first described in the 1950s, but early attempts at REBOA faced several technical challenges. Subsequent advances in endovascular technologies led to renewed interest in employing REBOA for management of hemorrhagic shock. However, REBOA usage remains infrequent, and indications for REBOA implementation remain unclear. We evaluated current opinions of trauma surgeons toward the use of REBOA for control of trauma-related hemorrhage and other causes of hemorrhagic shock. We hypothesize, that despite heightened interest in REBOA, implementation remains limited. A 25-question survey was thus created to query institutional and surgeon-specific training and practice patterns related to REBOA usage. The anonymized survey was distributed via email to a national trauma surgeon database and responses were recorded online. 992 subjects were invited to participate, of whom 31% (n=311) responded. Of these, 89% reported to be a trauma or acute care surgeon at a Level I trauma center, 50% reported practicing for ≥20 years. Two-thirds (68%) reported REBOA use at their institution, and the majority (59%) employed REBOA at least once. However, most (78%) performed ≤5 REBOA placements last year. Respondents supported REBOA usage in non-trauma causes of shock including gastrointestinal bleeding (60%), post-partum hemorrhage (83%), and ruptured abdominal aortic aneurysm (69%). A significant minority (20.3%) reported either only slight confidence or no confidence in their ability to deploy REBOA, and thus 21% reported being ‘very interested’ in attending a REBOA skills course.We thus conclude that REBOA has gained wide interest among trauma surgeons. However, placement remains infrequent with most providers placing a few annually. Educational courses are needed to disseminate the necessary skills for REBOA utilization.
Conflict of interest statement
Figures
Comment in
-
Trauma surgeons as the vanguard for safe REBOA implementation-response to letter to the editor.J Trauma Acute Care Surg. 2021 May 1;90(5):e127. doi: 10.1097/TA.0000000000003078. J Trauma Acute Care Surg. 2021. PMID: 33417409 Free PMC article. No abstract available.
-
Resuscitative endovascular balloon occlusion of the aorta on placenta accreta spectrum and its benefits for trauma patients.J Trauma Acute Care Surg. 2021 May 1;90(5):e126. doi: 10.1097/TA.0000000000003077. J Trauma Acute Care Surg. 2021. PMID: 33443986 No abstract available.
References
-
- Hughes CW. Use of an intra-aortic balloon catheter tamponade for controlling intra-abdominal hemorrhage in man. Surgery. 1954;36(1):65–8. - PubMed
-
- DuBose JJ, Scalea TM, Brenner M, Skiada D, Inaba K, Cannon J, Moore L, Holcomb J, Turay D, Arbabi CN, et al. The AAST prospective Aortic Occlusion for Resuscitation in Trauma and Acute Care Surgery (AORTA) registry: Data on contemporary utilization and outcomes of aortic occlusion and resuscitative balloon occlusion of the aorta (REBOA). J Trauma Acute Care Surg. 2016;81(3):409–19. - PubMed
-
- Matsumura Y, Matsumoto J, Kondo H, Idoguchi K, Ishida T, Kon Y, Tomita K, Ishida K, Hirose T, Umakoshi K, et al. Fewer REBOA complications with smaller devices and partial occlusion: evidence from a multicentre registry in Japan. Emerg Med J. 2017;34(12):793–9. - PubMed
-
- Moore LJ, Brenner M, Kozar RA, Pasley J, Wade CE, Baraniuk MS, Scalea T, Holcomb JB. Implementation of resuscitative endovascular balloon occlusion of the aorta as an alternative to resuscitative thoracotomy for noncompressible truncal hemorrhage. J Trauma Acute Care Surg. 2015;79(4):523–30; discussion 30–2. - PubMed
-
- Brenner ML, Moore LJ, DuBose JJ, Tyson GH, McNutt MK, Albarado RP, Holcomb JB, Scalea TM, Rasmussen TE. A clinical series of resuscitative endovascular balloon occlusion of the aorta for hemorrhage control and resuscitation. J Trauma Acute Care Surg. 2013;75(3):506–11. - PubMed
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical