Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Sep 19:2020:8830163.
doi: 10.1155/2020/8830163. eCollection 2020.

Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature

Affiliations

Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature

Hind F Abuhulaibah et al. Int J Dent. .

Abstract

Materials and methods: Forty-five files from each brand were randomly assigned to three groups (n = 15) and subjected to the following: no immersion (control), 1-minute immersion, and 5-minute immersion in 2.5% NaOCl at 37°C. CF for all the files was tested within a well-lubricated stainless-steel artificial canal in a water bath at 37°C simulating body temperature. The procedure was video recorded, and the number of cycles to fracture (NCF) was calculated by multiplying the time taken to fracture, with the number of rotations per second. The data were analyzed for normality, and thereafter, one-way ANOVA with multiple Bonferroni was used as the post hoc test.

Results: The resistance to CF of OC files was significantly higher than PTG files in all groups. In groups immersed in NaOCl for one minute, OC files showed significant drop in the CF resistance; PTG files showed a drop as well but not significantly. Both files demonstrated a significant drop in resistance to CF after immersion in NaOCl for five minutes compared to the control group.

Conclusion: OC files were significantly more resistant to CF compared to PTG in all groups. Immersion in 2.5% NaOCl for 5 minutes significantly reduced the resistance to CF for all the files.

PubMed Disclaimer

Conflict of interest statement

The authors declare that there are no conflicts of interest.

Similar articles

References

    1. Shen Y., Zhou H.-m., Zheng Y.-f., Peng B., Haapasalo M. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. Journal of Endodontics. 2013;39(2):163–172. doi: 10.1016/j.joen.2012.11.005. - DOI - PubMed
    1. Sch€afer E., Dzepina A., Danesh G. Bending properties of rotary nickel-titanium instruments. Oral Surgery, Oral Medicine, Oral Pathology, and Oral Radiology. 2003;96:757–763. - PubMed
    1. Pedullà E., Grande N. M., Plotino G., Pappalardo A., Rapisarda E. Cyclic fatigue resistance of three different nickel-titanium instruments after immersion in sodium hypochlorite. Journal of Endodontics. 2011;37(8):1139–1142. doi: 10.1016/j.joen.2011.04.008. - DOI - PubMed
    1. Parashos P., Messer H. H. Rotary NiTi instrument fracture and its consequences. Journal of Endodontics. 2006;32(11):1031–1043. doi: 10.1016/j.joen.2006.06.008. - DOI - PubMed
    1. Cheung G. S. P., Peng B., Bian Z., Shen Y., Darvell B. W. Defects in ProTaper S1 instruments after clinical use: fractographic examination. International Endodontic Journal. 2005;38(11):802–809. doi: 10.1111/j.1365-2591.2005.01020.x. - DOI - PubMed

LinkOut - more resources