Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2020 Sep 15:2020:8846920.
doi: 10.1155/2020/8846920. eCollection 2020.

Surface Electromyography as a Method for Diagnosing Muscle Function in Patients with Congenital Maxillofacial Abnormalities

Affiliations
Review

Surface Electromyography as a Method for Diagnosing Muscle Function in Patients with Congenital Maxillofacial Abnormalities

Liliana Szyszka-Sommerfeld et al. J Healthc Eng. .

Abstract

Electromyography (EMG) is the most objective and reliable method available for imaging muscle function and efficiency, which is done by identifying their electrical potentials. In global surface electromyography (sEMG), surface electrodes are located on the surface of the skin, and it detects superimposed motor unit action potentials from many muscle fibers. sEMG is widely used in orthodontics and maxillofacial orthopaedics to diagnose and treat temporomandibular disorders (TMD) in patients, assess stomatognathic system dysfunctions in patients with malocclusions, and monitor orthodontic therapies. Information regarding muscle sEMG activity in subjects with congenital maxillofacial abnormalities is limited. For this reason, the aim of this review is to discuss the usefulness of surface electromyography as a method for diagnosing muscle function in patients with congenital malformations of the maxillofacial region. Original papers on this subject, published in English between 1995 until 2020, are located in the MEDLINE/PubMed database.

PubMed Disclaimer

Conflict of interest statement

The authors declare that there are no conflicts of interest regarding the publication of this article.

References

    1. Woźniak K., Piątkowska D., Lipski M., Mehr K. Surface electromyography in orthodontics - a literature review. Medical Science Monitor. 2013;19:416–423. - PMC - PubMed
    1. Castroflorio T., Farina D., Bottin A., Piancino M. G., Bracco P., Merletti R. Surface EMG of jaw elevator muscles: effect of electrode location and inter-electrode distance. Journal of Oral Rehabilitation. 2005;32(6):411–417. doi: 10.1111/j.1365-2842.2005.01442.x. - DOI - PubMed
    1. Castroflorio T., Icardi K., Torsello F., Deregibus A., Debernardi C., Bracco P. Reproducibility of surface EMG in the human masseter and anterior temporalis muscle areas. Cranio. 2005;23(2):130–137. doi: 10.1179/crn.2005.018. - DOI - PubMed
    1. Castroflorio T., Icardi K., Becchino B., et al. Reproducibility of surface EMG variables in isometric sub-maximal contractions of jaw elevator muscles. Journal of Electromyography and Kinesiology. 2006;16(5):498–505. doi: 10.1016/j.jelekin.2005.08.007. - DOI - PubMed
    1. Ferrario V. F., Sforza C., Zanotti G., Tartaglia G. M. Maximal bite forces in healthy young adults as predicted by surface electromyography. Journal of Dentistry. 2004;32(6):451–457. doi: 10.1016/j.jdent.2004.02.009. - DOI - PubMed

MeSH terms