. 2021 Apr;31(4):2218-2226.
doi: 10.1007/s00330-020-07349-9. Epub 2020 Oct 8.

Noise reduction approach in pediatric abdominal CT combining deep learning and dual-energy technique

Affiliations

Noise reduction approach in pediatric abdominal CT combining deep learning and dual-energy technique

Seunghyun Lee et al. Eur Radiol. 2021 Apr.

Abstract

Objectives: To evaluate the image quality of low iodine concentration, dual-energy CT (DECT) combined with a deep learning-based noise reduction technique for pediatric abdominal CT, compared with standard iodine concentration single-energy polychromatic CT (SECT).

Methods: From December 2016 to May 2017, DECT with 300 mg•I/mL contrast medium was performed in 29 pediatric patients (17 boys, 12 girls; age, 2-19 years). The DECT images were reconstructed using a noise-optimized virtual monoenergetic reconstruction image (VMI) with and without a deep learning method. SECT images with 350 mg•I/mL contrast medium, performed within the last 3 months before the DECT, served as reference images. The quantitative and qualitative parameters were compared using paired t tests and Wilcoxon signed-rank tests, and the differences in radiation dose and total iodine administration were assessed.

Results: The linearly blended DECT showed lower attenuation and higher noise than SECT. The 60-keV VMI showed an increase in attenuation and higher noise than SECT. The combined 60-keV VMI plus deep learning images showed low noise, no difference in contrast-to-noise ratios, and overall image quality or diagnostic image quality, but showed a higher signal-to-noise ratio in the liver and lower enhancement of lesions than SECT. The overall image and diagnostic quality of lesions were maintained on the combined noise reduction approach. The CT dose index volume and total iodine administration in DECT were respectively 19.6% and 14.3% lower than those in SECT.

Conclusion: Low iodine concentration DECT, combined with deep learning in pediatric abdominal CT, can maintain image quality while reducing the radiation dose and iodine load, compared with standard SECT.

Key points: • An image noise reduction approach combining deep learning and noise-optimized virtual monoenergetic image reconstruction can maintain image quality while reducing radiation dose and iodine load. • The 60-keV virtual monoenergetic image reconstruction plus deep learning images showed low noise, no difference in contrast-to-noise ratio, and overall image quality, but showed a higher signal-to-noise ratio in the liver and a lower enhancement of lesion than single-energy polychromatic CT. • This combination could offer a 19.6% reduction in radiation dose and a 14.3% reduction in iodine load, in comparison with a control group that underwent single-energy polychromatic CT with the standard protocol.

Keywords: Child; Deep learning; Iodine; Radiation dosage; Tomography, X-ray computed.

PubMed Disclaimer

References

    1. You SK, Choi YH, Cheon JE et al (2019) Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study. Abdom Radiol (NY) 44:1928–1935 - DOI
    1. Zhang X, Li S, Liu W et al (2016) Double-low protocol for hepatic dynamic CT scan: effect of low tube voltage and low-dose iodine contrast agent on image quality. Medicine (Baltimore) 95:e4004 - DOI
    1. Smith EA, Dillman J (2016) Current role of body MRI in pediatric oncology. Pediatr Radiol 46(6):873–880 - DOI
    1. Schwarz F, Ruzsics B, Schoepf UJ et al (2008) Dual-energy CT of the heart-principles and protocols. Eur J Radiol 68:423–433 - DOI
    1. Agrawal MD, Oliveira GR, Kalva SP, Pinho DF, Arellano RS, Sahani DV (2016) Prospective comparison of reduced-iodine-dose virtual monochromatic imaging dataset from dual-energy CT angiography with standard-iodine-dose single-energy CT angiography for abdominal aortic aneurysm. AJR Am J Roentgenol 207:W125–W132 - DOI