Accuracy of a nucleocapsid protein antigen rapid test in the diagnosis of SARS-CoV-2 infection

Affiliations

Accuracy of a nucleocapsid protein antigen rapid test in the diagnosis of SARS-CoV-2 infection

Bo Diao et al. Clin Microbiol Infect. 2021 Feb.

Abstract

Objectives: Rapid, reliable and easy-to-implement diagnostics that can be adapted in early severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis are critical to combat the epidemic. SARS-CoV-2 nucleocapsid protein (NP) is an ideal target for viral antigen-based detection. A rapid and convenient method was developed based on fluorescence immunochromatographic (FIC) assay to detect the SARS-CoV-2 NP antigen. However, the accuracy of this diagnostic method needs to be examined.

Methods: This prospective study was carried out between 10 and 15 February 2020 in seven hospitals in Wuhan and one hospital in Chongqing, China. Participants with clinically suspected SARS-CoV-2 infection were enrolled. NP antigen testing by FIC assay and nucleic acid (NA) testing by real-time reverse transcriptase PCR (RT-PCR) were performed simultaneously in a blinded manner with the same nasopharyngeal swab sample. The diagnostic accuracy of NP antigen testing was calculated by taking NA testing of RT-PCR as the reference standard, in which samples with a cycle threshold (Ct) value of ≤40 were interpreted as positive for SARS-CoV-2.

Results: A total of 253 participants were enrolled; two participants were excluded from the analyses because of invalid NP testing results. Of 251 participants (99.2%) included in the diagnostic accuracy analysis, 201 (80.1%) had a Ct value of ≤40. With Ct value 40 as the cutoff of NA testing, the sensitivity, specificity and percentage agreement of the FIC assay was 75.6% (95% confidence interval, 69.0-81.3), 100% (95% confidence interval, 91.1-100) and 80.5% (95% confidence interval, 75.1-84.9) respectively.

Conclusions: With RT-PCR assay as the reference standard, NP antigen testing by FIC assay shows high specificity and relatively high sensitivity in SARS-CoV-2 diagnosis in the early phase of infection.

Keywords: Antigen detection; Diagnosis; Fluorescence immunochromatographic assay; Nucleocapsid protein; SARS-CoV-2.

PubMed Disclaimer

References

    1. Sharfstein J.M., Becker S.J., Mello M.M. Diagnostic testing for the novel coronavirus. JAMA. 2020;323:1437–1438. - PubMed
    1. Liu R., Han H., Liu F., Lv Z., Wu K., Liu Y. Positive rate of RT-PCR detection of SARS-CoV-2 infection in 4880 cases from one hospital in Wuhan, China, from Jan to Feb 2020. Clin Chim Acta. 2020;505:172–175. - PMC - PubMed
    1. Sun B., Feng Y., Mo X., Zheng P., Wang Qian, Li P. Kinetics of SARS-CoV-2 specific IgM and IgG responses in COVID-19 patients. Emerg Microbe. Infect. 2020;9:940–948. - PMC - PubMed
    1. Pan Y., Li X., Yang G., Fan J., Tang Y., Zhao J. Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients. J Infect. 2020;81:e28–e32. - PMC - PubMed
    1. Wölfel R., Corman V.M., Guggemos W., Seilmaier M., Zange S., Müller M.A. Virological assessment of hospitalized patients with COVID-2019. Nature. 2020;581:465–469. - PubMed

Publication types

MeSH terms