The foreign body reaction in total hip arthroplasties. A correlated light-microscopy, SEM, and TEM study
- PMID: 3304192
- DOI: 10.1007/BF00450457
The foreign body reaction in total hip arthroplasties. A correlated light-microscopy, SEM, and TEM study
Abstract
An in vivo histological and ultrastructural study of the cellular reaction to particulate material currently used in orthopaedic surgery produced evidence that, on a strictly cellular level, the main damage is done by the smallest particles produced by hip prostheses, i.e. metal particles, irrespective of differences in their chemical composition. Particle size and release rate are the critical factors, although other mechanisms of cellular damage may be active once granulation tissue is formed.
Similar articles
-
A histopathologic comparison of the tissue reaction to prosthetic materials in the knee joint of rats.Orthopedics. 1985 Oct;8(10):1276-80. doi: 10.3928/0147-7447-19851001-14. Orthopedics. 1985. PMID: 3912740
-
Widespread dissemination of metal debris from implants.J Bone Joint Surg Br. 1994 Sep;76(5):701-12. J Bone Joint Surg Br. 1994. PMID: 8083255
-
A failed vitallium/stainless steel total hip replacement: a case report with histological and metallurgical examination.J Biomed Mater Res. 1975 Sep;9(5):465-77. doi: 10.1002/jbm.820090509. J Biomed Mater Res. 1975. PMID: 1100635
-
Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses.Proc Inst Mech Eng H. 2006 Feb;220(2):355-69. doi: 10.1243/095441105X63291. Proc Inst Mech Eng H. 2006. PMID: 16669401 Review.
-
Biological effects of metal-on-metal hip replacements.Proc Inst Mech Eng H. 2006 Feb;220(2):379-84. doi: 10.1243/095441105X68971. Proc Inst Mech Eng H. 2006. PMID: 16669403 Review.
Cited by
-
Case report 816: Rapid acceleration of osteolysis from loose cemented total hip replacement.Skeletal Radiol. 1993 Nov;22(8):619-21. doi: 10.1007/BF00197148. Skeletal Radiol. 1993. PMID: 8291017 No abstract available.
-
Pathology of the bone-cement interface in loosening of total hip replacement.Arch Orthop Trauma Surg. 1990;109(2):83-8. doi: 10.1007/BF00439384. Arch Orthop Trauma Surg. 1990. PMID: 2317131
-
Fragmentation of methylmethacrylate: a cause of late failure of total hip replacement. A case report.Arch Orthop Trauma Surg. 1990;109(1):49-52. doi: 10.1007/BF00441911. Arch Orthop Trauma Surg. 1990. PMID: 2344268