Diagnostic accuracy of non-contact infrared thermometers and thermal scanners: a systematic review and meta-analysis
- PMID: 33043363
- PMCID: PMC7665626
- DOI: 10.1093/jtm/taaa193
Diagnostic accuracy of non-contact infrared thermometers and thermal scanners: a systematic review and meta-analysis
Abstract
Infrared thermal screening, via the use of handheld non-contact infrared thermometers (NCITs) and thermal scanners, has been widely implemented all over the world. We performed a systematic review and meta-analysis to investigate its diagnostic accuracy for the detection of fever. We searched PubMed, Embase, the Cochrane Library, medRxiv, bioRxiv, ClinicalTrials.gov, COVID-19 Open Research Dataset, COVID-19 research database, Epistemonikos, EPPI-Centre, World Health Organization International Clinical Trials Registry Platform, Scopus and Web of Science databases for studies where a non-contact infrared device was used to detect fever against a reference standard of conventional thermometers. Forest plots and Hierarchical Summary Receiver Operating Characteristics curves were used to describe the pooled summary estimates of sensitivity, specificity and diagnostic odds ratio. From a total of 1063 results, 30 studies were included in the qualitative synthesis, of which 19 were included in the meta-analysis. The pooled sensitivity and specificity were 0.808 (95%CI 0.656-0.903) and 0.920 (95%CI 0.769-0.975), respectively, for the NCITs (using forehead as the site of measurement), and 0.818 (95%CI 0.758-0.866) and 0.923 (95%CI 0.823-0.969), respectively, for thermal scanners. The sensitivity of NCITs increased on use of rectal temperature as the reference. The sensitivity of thermal scanners decreased in a disease outbreak/pandemic setting. Changes approaching statistical significance were also observed on the exclusion of neonates from the analysis. Thermal screening had a low positive predictive value, especially at the initial stage of an outbreak, whereas the negative predictive value (NPV) continued to be high even at later stages. Thermal screening has reasonable diagnostic accuracy in the detection of fever, although it may vary with changes in subject characteristics, setting, index test and the reference standard used. Thermal screening has a good NPV even during a pandemic. The policymakers must take into consideration the factors surrounding the screening strategy while forming ad-hoc guidelines.
Keywords: COVID-19; fever; infection control; influenza; infrared rays; mass screening; pandemics.
© International Society of Travel Medicine 2020. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Similar articles
-
The impact of age on comparative diagnostic accuracy of temporal artery thermometers and non-contact infrared thermometers for fever detection: a systematic review and meta-analysis.BMC Infect Dis. 2025 Jan 6;25(1):31. doi: 10.1186/s12879-024-10332-0. BMC Infect Dis. 2025. PMID: 39762771 Free PMC article.
-
Optimal diagnostic fever thresholds using non-contact infrared thermometers under COVID-19.Front Public Health. 2022 Nov 24;10:985553. doi: 10.3389/fpubh.2022.985553. eCollection 2022. Front Public Health. 2022. PMID: 36504995 Free PMC article.
-
Considerations and a call to action for the use of noncontact forehead infrared handheld thermometers during the COVID-19 pandemic.J Glob Health. 2021 Jan 30;11:03023. doi: 10.7189/jogh.11.03023. J Glob Health. 2021. PMID: 33692878 Free PMC article. No abstract available.
-
Reliability of Non-Contact Infrared Thermometers for Fever Screening Under COVID-19.Risk Manag Healthc Policy. 2022 Mar 10;15:447-456. doi: 10.2147/RMHP.S357567. eCollection 2022. Risk Manag Healthc Policy. 2022. PMID: 35300277 Free PMC article.
-
Thoracic imaging tests for the diagnosis of COVID-19.Cochrane Database Syst Rev. 2020 Sep 30;9:CD013639. doi: 10.1002/14651858.CD013639.pub2. Cochrane Database Syst Rev. 2020. Update in: Cochrane Database Syst Rev. 2020 Nov 26;11:CD013639. doi: 10.1002/14651858.CD013639.pub3. PMID: 32997361 Updated.
Cited by
-
Travel in the Time of COVID: A Review of International Travel Health in a Global Pandemic.Curr Infect Dis Rep. 2022;24(10):129-145. doi: 10.1007/s11908-022-00784-3. Epub 2022 Aug 4. Curr Infect Dis Rep. 2022. PMID: 35965881 Free PMC article. Review.
-
Globally deployed COVID-19 fever screening devices using infrared thermographs consistently normalize high readings to afebrile range.J Biomed Opt. 2021 Mar;26(4):043009. doi: 10.1117/1.JBO.26.4.043009. J Biomed Opt. 2021. PMID: 33715317 Free PMC article.
-
Heat and temperature.BJA Educ. 2022 Sep;22(9):350-356. doi: 10.1016/j.bjae.2022.06.002. Epub 2022 Jul 19. BJA Educ. 2022. PMID: 36033933 Free PMC article. Review. No abstract available.
-
Implementation of Thermal Camera for Non-Contact Physiological Measurement: A Systematic Review.Sensors (Basel). 2021 Nov 23;21(23):7777. doi: 10.3390/s21237777. Sensors (Basel). 2021. PMID: 34883780 Free PMC article.
-
Pulmonary Procedures During the COVID-19 Pandemic: A Work Group Report of the AAAAI Asthma Diagnosis and Treatment (ADT) Interest Section.J Allergy Clin Immunol Pract. 2022 Jun;10(6):1474-1484. doi: 10.1016/j.jaip.2022.02.044. Epub 2022 Apr 14. J Allergy Clin Immunol Pract. 2022. PMID: 35431153 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical