Impact of ictal subtraction SPECT and PET in presurgical evaluation
- PMID: 33058173
- DOI: 10.1111/ane.13362
Impact of ictal subtraction SPECT and PET in presurgical evaluation
Abstract
Objective: To assess the relative contribution of ictal subtraction single-photon emission computed tomography (ISSPECT) and 18 F-fluorodeoxyglucose positron emission tomography computed tomography (PET) in epilepsy surgery decision making.
Materials and methods: A retrospective 3-year study of consecutive patients with resistant focal epilepsy who underwent ISSPECT and PET to evaluate to what extent these modalities influence decisions in epilepsy surgery and outcomes. ISSPECT imaging was performed in 106 patients and 58 (55%) had PET also. The clinical consensus (ClinC) was the final arbiter for decisions. Post-surgical outcomes were collected from follow-up clinics. Non-parametric statistics were used to assess association and logistic regression to evaluate prediction of outcomes.
Results: Of 106 patients, 60 were males (57%). MRI was non-lesional in 46 (43%). Concordance with ClinC was seen in 80 patients (76%) for ISSPECT, in 46 patients (79%) for PET, and in 37 patients (64%) for ISSPECT + PET. Fifty-six patients (53%) were planned for intracranial video-electroencephalography monitoring (IVEM). Those with ClinC-PET concordance were likely to proceed to IVEM (p = 0.02). ClinC-PET concordance and ClinC-ISSPECT concordance did not predict decision to proceed to surgery, but VEM-MRI concordance did in lesional cases (p = 0.018). Forty-five (42%) underwent surgery of which 29 had minimum follow-up for 1 year (mean, 20 months; SD, 8) and 22 (76%) had Engel class I outcomes. ClinC-ISSPECT concordance (p = 0.024) and VEM-MRI concordance (p = 0.016) predicted Engel class I outcomes.
Conclusion: Those with ClinC-PET concordance were more likely to proceed with IVEM. ClinC-ISSPECT concordance and VEM-MRI concordance predicted good surgical outcomes.
Keywords: FDG-PET; Ictal subtraction SPECT; concordance; epilepsy surgery.
© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
References
REFERENCES
-
- Ollenberger GP, Byrne AJ, Berlangieri SU, et al. Assessment of the role of FDG PET in the diagnosis and management of children with refractory epilepsy. Eur J Nucl Med Mol Imaging. 2005;32(11):1311-1316.
-
- Knowlton RC. The role of FDG-PET, ictal SPECT, and MEG in the epilepsy surgery evaluation. Epilepsy Behav. 2006;8(1):91-101.
-
- Carter Snead O, Chen LS, Mitchell WG, et al. Usefulness of [18F]fluorodeoxyglucose positron emission tomography in pediatric epilepsy surgery. Pediatr Neurol. 1996;14(2):98-107.
-
- Ahnlide JA, Rosen I, Linden-Mickelsson Tech P, Kallen K. Does SISCOM contribute to favorable seizure outcome after epilepsy surgery? Epilepsia. 2007;48(3):579-588.
-
- Lee SK, Lee SY, Kim KK, Hong KS, Lee DS, Chung CK. Surgical outcome and prognostic factors of cryptogenic neocortical epilepsy. Ann Neurol. 2005;58(4):525-532.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources