Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas

Affiliations
Review

Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas

Maddalena De Bernardo et al. Clin Ophthalmol. .

Abstract

Myopia is one of the main risk factors for the onset of open-angle glaucoma. One of the first steps to assess glaucoma occurrence is the measurement of the intraocular pressure (IOP) by the Goldmann applanation tonometry (GAT). Even if this device is considered to be the gold standard for such measurements, it is affected by several sources of errors. Among these, there are the corneal thickness and curvature, both modified by corneal refractive surgery (CRS), that nowadays has become a very popular method to treat refractive errors. Indeed, CRS, by modifying the corneal shape and structure, causes an underestimation of the IOP measurements. In the literature, several IOP correction formulas to utilize with different devices have been proposed to overcome this problem. This paper aims to review the various correction formulas applied to the GAT in the attempt to improve the reliability of this measurement.

Keywords: GAT; IOP measurement; corneal refractive surgery; laser in situ keratomileusis; photorefractive keratectomy.

PubMed Disclaimer

Conflict of interest statement

The authors report no conflicts of interest for this work.

References

    1. Goldmann H, Schmidt T. Further contribution to applanation tonometry. Ophthalmologica. 1961;141(6):441–456. doi:10.1159/000304099 - DOI - PubMed
    1. Chihara E, Liu X, Dong J, et al. Severe myopia as a risk factor for progressive visual field loss in primary open glaucoma. Ophthalmologica. 1997;211(2):66–71. doi:10.1159/000310760 - DOI - PubMed
    1. Goldmann H, Schmidt T. Applanation tonometry. Ophthalmologica. 1957;134(4):221–242. doi:10.1159/000303213 - DOI - PubMed
    1. Whitacre MM, Stein R. Sources of error with use of Goldmann type tonometers. Surv Ophthalmol. 1993;38(1):1–30. doi:10.1016/0039-6257(93)90053-a - DOI - PubMed
    1. Rosa N, De Bernardo M. Central corneal thickness determination in corneal edema. Graefes Arch Clin Exp Ophthalmol. 2017;255(6):1251–1252. doi:10.1007/s00417-017-3634-9 - DOI - PubMed

LinkOut - more resources