Automated and hand-held breast US: effect on patient management
- PMID: 3306779
- DOI: 10.1148/radiology.165.1.3306779
Automated and hand-held breast US: effect on patient management
Erratum in
- Radiology 1988 May;167(2):582
Abstract
Breast ultrasound (US) was performed, with either an automated or a hand-held unit or both, on 1,212 patients. Of 612 asymptomatic patients, 118 (19.3%) had solitary cysts; ten (1.6%), multiple cysts; and 29 (4.7%), benign masses; however, US depicted only one (0.2%) nonpalpable mammographically undetected carcinoma. In 513 patients with palpable masses (n = 396) and with mammographically detected masses (n = 117), US was useful in avoiding an unnecessary biopsy in 113 (22.0%), leading to aspiration of a cyst in 26 (5.1%), monitoring multiple cysts in 31 (6.0%), avoiding aspiration of a solid mass in 65 (12.7%), supporting biopsy of an equivocal solid mass in 91 (17.7%), and demonstrating a nonpalpable mammographically detected carcinoma in six (1.2%). In 224 patients with either palpable or mammographically visible masses who underwent both methods of US, the 4.5-MHz or 3.9-MHz automated unit depicted the abnormality in 119 (53.1%) and the 7.5-MHz hand-held unit, in 171 (76.3%). Of 18 cancers evaluated with both methods, all were detected with the hand-held unit and only 12 were seen with the automated unit.
Similar articles
-
Real-time breast sonography: application in 300 consecutive patients.AJR Am J Roentgenol. 1986 Sep;147(3):479-86. doi: 10.2214/ajr.147.3.479. AJR Am J Roentgenol. 1986. PMID: 3526839
-
Follow-up of palpable circumscribed noncalcified solid breast masses at mammography and US: can biopsy be averted?Radiology. 2004 Dec;233(3):850-6. doi: 10.1148/radiol.2333031845. Epub 2004 Oct 14. Radiology. 2004. PMID: 15486217
-
High frequency breast ultrasound. Hand-held versus automated units; examination for palpable mass versus screening.J Ultrasound Med. 1988 Feb;7(2):77-81. doi: 10.7863/jum.1988.7.2.77. J Ultrasound Med. 1988. PMID: 3279228
-
[Stereotaxic fine-needle aspirations of clinically latent breast cysts: an efficient and neat procedure].Bull Cancer. 1997 Nov;84(11):1073-8. Bull Cancer. 1997. PMID: 9536989 Review. French.
-
[Management of a breast cystic syndrome: Guidelines].J Gynecol Obstet Biol Reprod (Paris). 2015 Dec;44(10):970-9. doi: 10.1016/j.jgyn.2015.09.043. Epub 2015 Oct 31. J Gynecol Obstet Biol Reprod (Paris). 2015. PMID: 26527028 Review. French.
Cited by
-
Benefit of ultrasonography in the detection of clinically and mammographically occult breast cancer.World J Surg. 2008 Dec;32(12):2593-8. doi: 10.1007/s00268-007-9273-2. World J Surg. 2008. PMID: 17960454
-
Optimal scanning technique to cover the whole breast using an automated breast volume scanner.Jpn J Radiol. 2010 May;28(4):325-8. doi: 10.1007/s11604-010-0424-2. Epub 2010 May 29. Jpn J Radiol. 2010. PMID: 20512554
-
Combined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast.BMC Cancer. 2014 Nov 3;14:798. doi: 10.1186/1471-2407-14-798. BMC Cancer. 2014. PMID: 25366878 Free PMC article.
-
Automatic breast ultrasound: state of the art and future perspectives.Ecancermedicalscience. 2020 Jun 23;14:1062. doi: 10.3332/ecancer.2020.1062. eCollection 2020. Ecancermedicalscience. 2020. PMID: 32728378 Free PMC article. Review.
-
Combination of digital mammography with semi-automated 3D breast ultrasound.Technol Cancer Res Treat. 2004 Aug;3(4):325-34. doi: 10.1177/153303460400300402. Technol Cancer Res Treat. 2004. PMID: 15270583 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources