Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Sep:30:1-8.
doi: 10.1016/j.carrev.2020.09.036. Epub 2020 Oct 1.

ImpaCt of an Optimal Implantation Strategy on Absorb Long-Term Outcomes: The CIAO Registry

Affiliations

ImpaCt of an Optimal Implantation Strategy on Absorb Long-Term Outcomes: The CIAO Registry

Claudio Rapetto et al. Cardiovasc Revasc Med. 2021 Sep.

Abstract

Aim: To compare the long-term outcomes of patients implanted with Absorb bioresorbable scaffold (BRS) with optimal versus suboptimal technique.

Methods and results: All patients who received an Absorb between March 2012 and January 2016 were selected from 19 Italian centers databases to assess the impact of an optimal implantation technique (CIAO criteria) on long-term device-oriented composite end-point (DOCE) - including cardiac death (CD), target-vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) - on its single components and on scaffold thrombosis (ScT). CIAO criteria consist of predilation (balloon/vessel ratio 1:1), correct sizing (BRS/proximal reference vessel diameter -RVD- ratio 0.8-1.2) and high-pressure postdilation with non-compliant (NC) balloon (≥20 atm for balloon/BRS ratio 1:1 or ≥16 atm for a 0.25-0.5 mm oversized balloon). Among the 1.434 patients analyzed, 464 (32.4%) fulfilled all CIAO criteria for every BRS implanted (CIAO 3 group), while 970 (67.6%) did not in at least one of the received BRS (CIAO 0-1-2 group). At 31.0 (interquartile range -IQR- 24.8-38.5) months follow-up, CIAO criteria did not impact on DOCE (8.2% vs. 8.0%, p = 0.92), ID-TLR (6.9% vs. 7.1%, p = 0.72) or ScT (1.9% vs. 1.8%, p = 0.80) in the overall population. At multivariate analysis overall BRS length (p = 0.001), severely calcified lesions (p = 0.03) and absence of CIAO criteria (CIAO 0, p = 0.005) were independent predictors of DOCE in long-term follow-up.

Conclusion: Our data suggest that strict application of an optimal Absorb implantation technique doesn't improve long-term DOCE or ScT but may mitigate the worse outcome of patients with calcific lesions.

Keywords: Bioresorbable scaffold; Coronary artery disease; Percutaneous coronary intervention.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest B.C., A.S.P. and F.R. report being member of the advisory board of Abbott Vascular and speakers' honoraria from Abbott Vascular; E.C., M.D.C. and F.V. reports speakers' honoraria from Abbott Vascular. The other authors have no conflict of interest to declare.

Comment in