Metal on Metal Bearing in Total Hip Arthroplasty and Its Impact on Synovial Cell Count
- PMID: 33081071
- PMCID: PMC7603093
- DOI: 10.3390/jcm9103349
Metal on Metal Bearing in Total Hip Arthroplasty and Its Impact on Synovial Cell Count
Abstract
Introduction: The effect of different bearings on synovial white blood cell (WBC) count and polymorphonuclear percentage (PMN%) in aspirations remains unclear. Therefore, this study investigates the impact of aseptic Metal-on-Metal (MoM) bearing on synovial fluid.
Methods: We searched our arthroplasty registry for aseptic painful THAs with MoM bearings between 2011 and 2018. Then, a case-matched control group was selected with septic and aseptic Total Hip Arthroplasty (THA) with ceramic on a polyethylene (PE) bearing. The matching criteria consisted of gender, age +/-10 years, and time of aspiration (+/-2years). Periprosthetic Joint Infection (PJI) was defined according to the Infectious Diseases Society of America (IDSA), and Musculoskeletal Infection Society (MSIS) using bacterial cultures, sonication and histology.
Results: In total, 19 patients who underwent hip aspiration with MoM bearing were identified. Five patients had to be excluded due to insufficient synovial fluid obtained (n = 2) or bacterial growth after sonication that was initially negative with the standard microbiological cultures (n = 3). As such, 14 were included. These patients were matched with 14 aseptic and 14 septic THAs with ceramic on a PE bearing, which constituted the control group. The mean serum chrome level was 20.0 ± 15.5 nmol/L and cobalt level 18.4 ± 22.1 nmol/L. The synovial WBC and PMN% varied significantly between MoM bearing group and the aseptic THA ceramic PE group (both p < 0.001), as well as the septic THA group (WBC p = 0.016, PMN% p < 0.001). Furthermore, the septic THA group had significantly higher CRP values than the aseptic MoM group (p = 0.016).
Conclusion: MoM bearing shows significantly higher synovial WBC and PMN% when compared to aseptic THA with ceramic on PE bearing above the MSIS cut-off. This is an important consideration when diagnosing periprosthetic joint infection using the MSIS guidelines.
Keywords: aspiration; cell count; infection; marker; metal on metal; total hip arthroplasty.
Conflict of interest statement
The authors declare no conflict of interest.
Similar articles
-
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion?Clin Orthop Relat Res. 2015 Feb;473(2):498-505. doi: 10.1007/s11999-014-3902-5. Clin Orthop Relat Res. 2015. PMID: 25171935 Free PMC article.
-
What Is the Impact of Automated Synovial Cell Counting on Different Aseptic Causes and Periprosthetic Conditions Associated With Revision THA?Clin Orthop Relat Res. 2022 May 1;480(5):905-914. doi: 10.1097/CORR.0000000000002063. Epub 2021 Dec 1. Clin Orthop Relat Res. 2022. PMID: 34851871 Free PMC article.
-
Increased Synovial Inflammatory Markers in Aseptic Total Hip Arthroplasty Dislocation.J Arthroplasty. 2020 May;35(5):1412-1416. doi: 10.1016/j.arth.2019.12.034. Epub 2019 Dec 21. J Arthroplasty. 2020. PMID: 31948812
-
Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome.Dan Med J. 2017 Mar;64(3):B5350. Dan Med J. 2017. PMID: 28260601 Review.
-
Sonication of Arthroplasty Implants Improves Accuracy of Periprosthetic Joint Infection Cultures.Clin Orthop Relat Res. 2017 Jul;475(7):1827-1836. doi: 10.1007/s11999-017-5315-8. Clin Orthop Relat Res. 2017. PMID: 28290115 Free PMC article. Review.
Cited by
-
Mild aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL)-type reactions also present in patients with failed knee prostheses.Bone Joint Res. 2024 Apr 4;13(4):149-156. doi: 10.1302/2046-3758.134.BJR-2023-0255.R1. Bone Joint Res. 2024. PMID: 38569600 Free PMC article.
-
Timepoint of aspiration can impact diagnostic of PJI - synovial fluid analyses exhibit a high intraindividual variation in periprosthetic joint infections of the knee.Arch Orthop Trauma Surg. 2025 Apr 29;145(1):276. doi: 10.1007/s00402-025-05888-8. Arch Orthop Trauma Surg. 2025. PMID: 40299053 Free PMC article.
-
Evaluating the Diagnostic Utility of Serum Laboratory Studies and Synovial Fluid Analysis in Identifying Periprosthetic Joint Infection in Metal Hip Revisions.Cureus. 2024 Oct 4;16(10):e70823. doi: 10.7759/cureus.70823. eCollection 2024 Oct. Cureus. 2024. PMID: 39493033 Free PMC article.
-
Laser Additive Manufacturing of Anti-Tetrachiral Endovascular Stents with Negative Poisson's Ratio and Favorable Cytocompatibility.Micromachines (Basel). 2022 Jul 18;13(7):1135. doi: 10.3390/mi13071135. Micromachines (Basel). 2022. PMID: 35888952 Free PMC article.
References
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous