Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2020 Oct:60 Suppl 6:S75-S85.
doi: 10.1111/trf.16076.

Viscoelastic testing in pediatric patients

Affiliations
Review

Viscoelastic testing in pediatric patients

Thorsten Haas et al. Transfusion. 2020 Oct.

Abstract

A tailored transfusion algorithm based on viscoelastic testing in the perioperative period or in trauma patients is recommended by guidelines for bleeding management. Bleeding management strategies in neonates and children are mostly extrapolated from the adult experience, as published evidence in the youngest age group is scarce. This manuscript is intended to give a structured overview of what has been published on the use of viscoelastic testing to guide bleeding management in neonates and children. Several devices that use either the traditional viscoelastic method or resonance viscoelastography technology are on the market. Reference ranges for children have been evaluated in only some of them. As most of the hemostasis maturation processes can be observed during the first year of life, adult reference ranges for viscoelastic testing could be applied over the age of 1 year. The majority of the published trials in children are based on retrospective analyses describing the correlation between viscoelastic testing and standard laboratory testing or focusing on the prediction of bleeding. Clinically more relevant studies in pediatric patients undergoing cardiac surgery have demonstrated that the implementation of a transfusion algorithm based on viscoelastic testing has significantly reduced transfusion requirements and that this approach has enabled a rapid detection of coagulation disorders in the presence of excessive bleeding. Although further studies are urgently needed, experts have reviewed the use of a transfusion algorithm based on viscoelastic testing in children as a feasible approach, as it has been shown to improve bleeding management and rationalize blood product transfusion.

PubMed Disclaimer

References

REFERENCES

    1. Weber CF, Gorlinger K, Meininger D, et al. Point-of-care testing: a prospective, randomized clinical trial of efficacy in coagulopathic cardiac surgery patients. Anesthesiology. 2012;117:531-547.
    1. Karkouti K, Callum J, Wijeysundera DN, et al. Point-of-care hemostatic testing in cardiac surgery: a stepped-wedge clustered randomized controlled trial. Circulation. 2016;134:1152-1162.
    1. Kozek-Langenecker SA, Ahmed AB, Afshari A, et al. Management of severe perioperative bleeding: guidelines from the European Society of Anaesthesiology: first update 2016. Eur J Anaesthesiol. 2017;34:332-395.
    1. Task Force on Patient Blood Management for Adult Cardiac Surgery of the European Association for Cardio-Thoracic Surgery (EACTS) and the European Association of Cardiothoracic A Anaesthesiology (EACTA), Boer C, Meesters MI, et al. 2017 EACTS/EACTA guidelines on patient blood management for adult cardiac surgery. J Cardiothorac Vasc Anesth. 2018;32:88-120.
    1. Spahn DR, Bouillon B, Cerny V, et al. The European guideline on management of major bleeding and coagulopathy following trauma: fifth edition. Crit Care. 2019;23:98.

MeSH terms

LinkOut - more resources